2.
Run:
interface
interface-type
interface-number
The interface view is displayed.
3.
Run:
isis timer lsp-throttle
throttle-interval
[
count
count
]
The minimum interval at which LSPs are sent is set.
The
count
parameter specifies the maximum number of LSPs that can be sent within
the interval specified by
throttle-interval
. The value of
count
is an integer ranging
from 1 to 1000.
l
Enable LSP fast flooding.
1.
Run:
system-view
The system view is displayed.
2.
Run:
isis
[
process-id
]
The IS-IS view is displayed.
3.
Run:
flash-flood
[
lsp-count
|
max-timer-interval
interval
| [
level-1
|
level-2
] ]
*
The LSP fast flooding is enabled.
Running the
flash-flood
command speeds up LSP flooding. The
lsp-count
parameter
specifies the number of LSPs flooded each time, which is applicable to all interfaces.
If the number of LSPs to be sent is greater than the value of
lsp-count
,
lsp-count
takes
effect. If the number of LSPs to be sent is smaller than the value of
lsp-count
, LSPs
of the actual number are sent. If a timer is configured and the configured timer does
not expire before the route calculation, the LSPs are flooded immediately when being
received; otherwise, the LSPs are sent when the timer expires.
When LSP fast flooding is enabled, Level-1 LSPs and Level-2 LSPs are fast flooded
by default if no level is specified.
l
Set an interval at which LSPs are retransmitted over a P2P link.
1.
Run:
system-view
The system view is displayed.
2.
Run:
interface
interface-type
interface-number
The interface view is displayed.
3.
Run:
isis timer lsp-retransmit
retransmit-interval
The interval at which LSPs are retransmitted over a P2P link is set.
----End
S6700 Series Ethernet Switches
Configuration Guide - IP Routing
6 IS-IS Configuration
Issue 01 (2012-03-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.