Step 3 Remove the TPM from the HFC. See step (2) in
.
Step 4 Place the removed TPM in an ESD bag.
----End
5.10.4 Installing a TPM or TCM
This topic describes how to install a trusted platform module (TPM) or trusted
cryptography module (TCM).
Scenarios
Install a TPM or TCM if:
●
A TPM or TCM has failed.
●
A TPM or TCM needs to be replaced with a new model.
A TPM and a TCM are similar in terms of appearance and replacement procedure. This topic
describes how to install a TPM.
Prerequisites
Conditions
●
You have powered off the RH8100 V3. For details, see
. Then you have removed all power cables from the server.
●
You have removed the High-performance Fusion Console (HFC) from the
RH8100 V3. For details, see
.
Data
●
You have obtained the cabinet number and chassis number of the RH8100 V3.
●
You have located the RH8100 V3 based on the preceding information, and
labeled its panel to prevent misoperations.
●
You have determined the position on the RH8100 V3 for installing a TPM.
Tools
●
ESD gloves
●
M3 Phillips screwdriver
●
Packaging materials, for example, an ESD bag
Hardware
Spare TPM
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves. For details, see
.
Step 2 Take the spare TPM out of its ESD bag.
RH8100 V3 Server
User Guide
5 Removing and Installing Parts of the RH8100 V3
Issue 30 (2019-12-19)
Copyright © Huawei Technologies Co., Ltd.
268