231
Field Description
oversize packets
Number of oversize packets received during the sampling interval.
Oversize packets are longer than 1518 octets (excluding framing bits but
including FCS octets).
fragments
Number of undersize packets with CRC errors received during the sampling
interval.
jabbers
Number of oversize packets with CRC errors received during the sampling
interval.
collisions
Number of colliding packets received during the sampling interval.
utilization
Bandwidth utilization (in hundreds of a percent) during the sampling period.
Related commands
rmon history
display rmon prialarm
Use
display rmon prialarm
to display information about RMON private alarm entries.
Syntax
display rmon prialarm
[
entry-number
]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
entry-number
: Specifies an alarm entry index in the range of 1 to 65535. If you do not specify an entry,
the command displays all private alarm entries.
Examples
# Display information about all RMON private alarm entries.
<Sysname> display rmon prialarm
PrialarmEntry 1 owned by user1 is VALID.
Sample type : absolute
Variable formula : (.1.3.6.1.2.1.16.1.1.1.6.1*100/.1.3.6.1.2.1.16.1.1.1.5.1)
Description : ifUtilization.GigabitEthernet1/0/1
Sampling interval (in seconds) : 10
Rising threshold : 80(associated with event 1)
Falling threshold : 5(associated with event 2)
Alarm sent upon entry startup : risingOrFallingAlarm
Entry lifetime : forever
Latest value : 85