176
</hello>
# Retrieve data in the
Name
column with the ifindex value not less than 5000 in the Interfaces table
under the Ifmgr module.
<rpc message-id="100"
xmlns="urn:ietf:params:xml:ns:netconf:base:1.0"
xmlns:nc="http://www.hp.com/netconf/base:1.0">
<get>
<filter type="subtree">
<top xmlns="http://www.hp.com/netconf/data:1.0">
<Ifmgr>
<Interfaces>
<Interface>
<IfIndex hp:match="notLess:5000"/>
<Name/>
</Interface>
</Interfaces>
</Ifmgr>
</top>
</filter>
</get>
</rpc>
Verifying the configuration
If the client receives the following text, the operation is successful:
<?xml version="1.0" encoding="UTF-8"?>
<rpc-reply xmlns="urn:ietf:params:xml:ns:netconf:base:1.0"
xmlns:nc="http://www.hp.com/netconf/base:1.0" message-id="100">
<data>
<top xmlns="http://www.hp.com/netconf/data:1.0">
<Ifmgr>
<Interfaces>
<Interface>
<IfIndex>7241</IfIndex>
<Name>NULL0</Name>
</Interface>
<Interface>
<IfIndex>7243</IfIndex>
<Name>Register-Tunnel0</Name>
</Interface>
</Interfaces>
</Ifmgr>
</top>
</data>
</rpc-reply>
Performing CLI operations through NETCONF
You can enclose command lines in XML messages to configure the device.