Description
Update BFD timer intervals for all the sessions under the current VLAN.
Options
min-transmit-interval
Update the minimum transmit interval of the BFD session.
min-receive-interval
Update the minimum receive interval of the BFD session.
detect-multiplier
Update the detect multiplier count of the BFD session.
txseconds
The time interval, in the range 1 to 20 seconds, between the transmission of two BFD hello packets.
rxseconds
The time interval, in the range 0 to 20 seconds, between the reception of two BFD hello packets.
0 indicates the local end is not interested in receiving hello packets from the peer.
multiplier
Number of BFD packets, in the range 1 to 5, that are allowed to be missed before BFD session times out.
NOTE:
• If
min-transmit-interval
or
min-receive-interval
value is configured as 1 sec, the
value of detect multiplier should be at least 3.
• If detect multiplier value is 1, the value of
min-transmit-interval
and
min-receive-
interval
should be at least 3 sec.
Set intervals configuration
; J9850A Configuration Editor; Created on release #KB.16.02.0000x
; Ver #0b:fc.59.f4.7b.ff.ff.fc.ff.ff.3f.ef:0d
hostname "switch"
module A type j9989a
module C type j9550a
module F type j9987a
snmp-server community "public" unrestricted
oobm
ip address dhcp-bootp
exit
vlan 1
name "DEFAULT_VLAN"
untagged A2-A24,C1-C24,F1-F24
ip address dhcp-bootp
exit
ip routing
router ospf
area 0.0.0.2
area 0.0.0.3
area backbone
enable
exit
bfd enable
Chapter 18 Bidirectional Forwarding Detection (BFD)
413