1U servers - Six drive bays are assigned to each of the four servers.
◦
2U servers - 12 drive bays are assigned to each of the two servers.
• Drive bay mapping is supported in this drive configuration. Use the iLO web interface or the iLO RESTful API (the iLO
Redfish API conformant) to assign the drives to specific server nodes for customized drive allocations to match
specific workloads. For more information, see the Drive bay mapping section in the HPE iLO user guide on the Hewlett
Packard Enterprise website (
https://www.hpe.com/support/ilo-docs).
Drive LEDs and buttons
Low-profile LFF drive LED definitions
Item
LED
Status
Definition
1
Fault
\Locate
Solid amber
The drive has failed.
Solid blue
The drive is operating normally and being identified by a
management application.
Flashing amber/blue
(1 flash per second)
The drive has failed, or a predictive failure alert has been received for
this drive; it also has been identified by a management application.
Flashing amber
(1 flash per second)
A predictive failure alert has been received for this drive. Replace the
drive as soon as possible.
2
Online
\Activity
Solid green
The drive is online and has no activity.
Flashing green
(4 flashes per second)
The drive is operating normally and has activity.
Table Continued