NOTE:
To purchase a FailSafe key, contact your authorized HP reseller or service provider, or see
the HP Web site for ordering information.
1.
Disconnect power from the system (see
Predisassembly procedures on page 52
).
2.
Remove the side access panel (see
Side access panel on page 58
).
3.
Remove top cover.
4.
Disconnect the solenoid cable from the system board (1), as shown:
Figure 4-8
Removing the Smart Cover Lock solenoid assembly
5.
Use the FailSafe key (T-15 wrench) to remove the two screws from the back of the chassis (2).
6.
Slide the solenoid assembly away from the chassis and out of the workstation (3).
Replacing the smart cover lock solenoid
To replace the Smart Cover Lock Solenoid assembly, reverse the previous removal steps.
Reinstalling the workstation top cover
To reinstall the workstation top cover:
1.
Place the top cover on top of the workstation chassis and align the six locking hooks on the
underside of the cover. Ensure that the locking hooks insert into the latch openings on the top of
the chassis.
Ensure that the open end of each locking hooks is facing toward the workstation front panel.
2.
With the locking hooks inserted into the latch openings, push the top cover forward toward the front
panel of the chassis until it snaps into the locked position.
3.
Reinstall the front bezel and the workstation side access panel.
60
Chapter 4 Removal and replacement procedures
ENWW
Содержание Xw6600 - Workstation - 2 GB RAM
Страница 1: ...HP xw6600 Workstation Service and Technical Reference Guide ...
Страница 10: ...x ENWW ...
Страница 114: ...104 Chapter 4 Removal and replacement procedures ENWW ...
Страница 154: ...144 Chapter 7 Configuring password security and resetting CMOS ENWW ...
Страница 166: ...156 Appendix A Appendix A Connector pins ENWW ...