![HP Xw6600 - Workstation - 2 GB RAM Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/hp/xw6600-workstation-2-gb-ram/xw6600-workstation-2-gb-ram_technical-reference-manual_156427053.webp)
In a two-drive workstation that has a boot drive and a data drive, you can apply the DriveLock feature
to the data drive only. In this case, the workstation can always boot, but the data drive is accessible only
when the DriveLock password is entered.
Cold boots require that you enter DriveLock passwords. However, DriveLock passwords are also
required for warm boots. For example, if you boot to DOS and press
Ctrl+Alt+Del
, you must enter the
DriveLock password before the workstation completes the next boot cycle. This warm-boot behavior is
consistent with the DriveLock feature.
Hood lock solenoid (smart cover lock)
The optional Hood lock solenoid (smart cover lock) provides a locking solenoid that can prevent the side
access cover from being removed from the workstation. When activated, the Hood lock solenoid
prevents unauthorized access to the internal workstation components. The lock solenoid is controlled
by the Lock and Unlock F10 Setup option for the hood lock. Access the F10 Setup functions is controlled
by the setup password.
CAUTION:
For maximum workstation access security, you must also establish a setup password. The
setup password prevents unauthorized access to the Computer Setup utility, thereby protecting the
integrity of the hood lock solenoid password.
Locking the solenoid lock
To activate the Hood lock solenoid:
1.
Power on or restart the workstation.
2.
As soon as the workstation is powered on, press and hold the
F10
key until you enter Computer
Setup. Press
Enter
to bypass the title screen, if necessary.
NOTE:
If you do not press the
F10
key at the appropriate time, you must restart the workstation
and press and hold the
F10
key again to access the utility.
If you are using a PS2 keyboard, you might see a Keyboard Error message—disregard it.
3.
Select
Security>Smart Cover>Cover Lock>Lock
.
4.
Select
Fire>Save Changes and Exit
.
Unlocking the solenoid lock
1.
Turn on or restart the workstation.
2.
As soon as the workstation is powered on, press and hold the
F10
key until you enter Computer
Setup. Press
Enter
to bypass the title screen, if necessary.
NOTE:
If you do not press the
F10
key at the appropriate time, you must restart the workstation
and press and hold the
F10
key again to access the utility.
If you are using a PS2 keyboard, you might see a Keyboard Error message—disregard it.
3.
Select
Security>Smart Cover>Cover Lock>Unlock
.
4.
Select
Fire>Save Changes and Exit
.
ENWW
Workstation management
43
Содержание Xw6600 - Workstation - 2 GB RAM
Страница 1: ...HP xw6600 Workstation Service and Technical Reference Guide ...
Страница 10: ...x ENWW ...
Страница 114: ...104 Chapter 4 Removal and replacement procedures ENWW ...
Страница 154: ...144 Chapter 7 Configuring password security and resetting CMOS ENWW ...
Страница 166: ...156 Appendix A Appendix A Connector pins ENWW ...