![HP X5000 G2 Скачать руководство пользователя страница 147](http://html.mh-extra.com/html/hp/x5000-g2/x5000-g2_administrators-manual_162912147.webp)
REBOOT SERVER
Syntax
REBOOT SERVER { ALL | <bay#> [{ , | - } <bay#>]} [FORCE] [{NORMAL | PXE
| HDD | RBSU }]
Description
Sends an asynchronous request to the server to do a graceful shutdown of the OS. After the OS
has had sufficient time to perform a graceful shutdown, the server blade is power cycled. If the
FORCE option is specified, the server blade OS is not given the opportunity to perform a graceful
shutdown before power is removed but is cleanly powered off and then immediately powered
back on. The FORCE option can cause a server blade to lose data and possibly to become unstable.
Restrictions
This command functions only if the enclosure power is already on. Because the EMU hardware
cannot determine if a blade is physically present unless enclosure power is on, the EM reports the
warning that the blade is not present if this command is used when enclosure power is off.
SET SERVER UID
Syntax
SET SERVER UID { ALL | <bay#> [{ , | - } <bay#>]} { ON | OFF }
Description
Turns on or off the UID LED on the specified servers.
Restrictions
This command functions only if the enclosure power is already on.
NOTE:
Because the EMU hardware cannot determine if a blade is physically present unless
enclosure power is on, the EM reports the warning that the blade is not present if this command
is used when enclosure power is off.
SET SERVER BOOT
Syntax
SET SERVER BOOT { FIRST | ONCE } { NORMAL | HDD | PXE | RBSU } { ALL |
<bay#> [{ , | - } <bay#>]}
Description
Persistently stores a setting for the IPL to be passed to the specified servers at the next reboot.
SET SERVER BOOT FIRST
sets the boot order of the blade.
SET SERVER BOOT ONCE
sets the boot device to be used on the next boot of the specified bay;
The RBSU option is only available for
SET SERVER BOOT ONCE
.
Restrictions
•
This setting is only valid on present blades and is cleared if the blade is removed.
•
This command functions only if the enclosure power is already on. Because the EMU hardware
cannot determine if a blade is physically present unless enclosure power is on, the EM reports
the warning that the blade is not present if this command is used when enclosure power is
off.
Server management
147
Содержание X5000 G2
Страница 166: ...German laser notice Italian laser notice Japanese laser notice 166 Regulatory compliance notices ...
Страница 173: ...Battery replacement notices Dutch battery notice French battery notice Battery replacement notices 173 ...
Страница 174: ...German battery notice Italian battery notice 174 Regulatory compliance notices ...
Страница 175: ...Japanese battery notice Spanish battery notice Battery replacement notices 175 ...