HP X5000 G2 Скачать руководство пользователя страница 1

HP X5000 G2 Network Storage System
Administrator Guide

Abstract

This document explains how to install, configure, and maintain all models of the HP X5000 G2 Network Storage System and
is intended for system administrators. For the latest version of this guide, go to

www.hp.com/support/manuals

. Select

NAS

Systems

in the storage group, and then select an X5000 G2 product.

HP Part Number: QW919-96035
Published:

 July

201

3

Edition:

4

Содержание X5000 G2

Страница 1: ...e and maintain all models of the HP X5000 G2 Network Storage System and is intended for system administrators For the latest version of this guide go to www hp com support manuals Select NAS Systems in the storage group and then select an X5000 G2 product HP Part Number QW919 96035 Published July 2013 Edition 4 ...

Страница 2: ... Server are registered trademarks of Microsoft Corporation in the United States and other countries Revision History Description Software Version Date Edition First release 2 01 0a November 201 1 First Corrected network addresses for iLO connections clarified network connections to both server blades are required during initial configuration added details 2 02 0a March 2012 Second to the Known Iss...

Страница 3: ...rts 22 Configuring Alerts and Email 22 HP System Management Homepage 26 Starting the System Management Homepage application 26 System Management Homepage main page 26 Using the System Manager 30 Component LEDs 34 EMU CLI SHOW commands 42 Known issues 43 Using Storage Viewer 47 HP Support websites 49 HP Insight Remote Support software 50 Microsoft Systems Center Operations Manager 51 Windows Recove...

Страница 4: ...ing the server blade backplane 82 Removing and replacing the server airflow baffle 84 Removing and replacing the front bezel standard 85 Removing and replacing the front bezel full 87 Removing and replacing the front LED display board in the rack standard 88 Removing and replacing the front LED display board full 89 Removing and replacing a drive drawer 91 Removing and replacing the drive drawer h...

Страница 5: ...t Password Fp 159 Set DHCP IP Address dH 159 Set Link Local IP Address LL 159 Display Current IP Address IP 159 Exit Button Menu 160 B Regulatory compliance notices 161 Regulatory compliance identification numbers 161 Federal Communications Commission notice 161 FCC rating label 161 Class A equipment 161 Class B equipment 161 Modification 162 Cables 162 Canadian notice Avis Canadien 162 Class A eq...

Страница 6: ...ch recycling notice 169 German recycling notice 169 Greek recycling notice 170 Hungarian recycling notice 170 Italian recycling notice 170 Latvian recycling notice 170 Lithuanian recycling notice 171 Polish recycling notice 171 Portuguese recycling notice 171 Romanian recycling notice 171 Slovak recycling notice 172 Spanish recycling notice 172 Swedish recycling notice 172 Turkish recycling notice...

Страница 7: ... Lower overall TCO with reduced footprint and lower energy consumption Specially developed setup tools setup wizards provide guided setup assistance performing many of the complex and time consuming tasks needed to configure and deploy a high availability storage system The setup tools make it easy to get both Windows and a two node cluster configured and running quickly HP and Microsoft managemen...

Страница 8: ...ng system software contains the Microsoft iSCSI Software Target and a Microsoft Cluster Service license The storage system configuration also includes the HP Initial Configuration Tasks window and HP Server Manager which are used to set up and manage your storage system The Initial Configuration Tasks window assists during the initial out of box setup by configuring the network configuring two nod...

Страница 9: ... Agreement HP X5000 G2 System Recovery DVD Certificate of Authenticity Card Safety and Disposal Documentation CD Locate and record the product number serial number and SAID number Before you begin installation locate and record the product number of the storage system serial number and support contract service agreement ID SAID number The product number of the storage system and serial number are ...

Страница 10: ...tors visible and accessible Figure 3 Storage system installed in a rack 1 Storage system enclosure 2 5 Disk enclosures optional 6 7 Cable connection with no bend radius smaller than 5 cm 2 If you purchased disk enclosures rack and cable the disk enclosures before moving to the next step 3 Cable the storage system to your network and attach the power cords See Rear view page 8 for connecting the po...

Страница 11: ...th two disk enclosures 1 X5000 G2 2 3 Disk enclosures 4 SAS cable connecting disk enclosure 1 green cable 5 Green color code for upper SAS I O module 6 Red color code for lower SAS I O module 7 SAS cable connecting disk enclosure 2 red cable Figure 5 page 12 shows an X5000 G2 Network Storage System with four disk enclosures Cable disk enclosures 1 1 ...

Страница 12: ...or lower SAS I O module 9 SAS cable connecting disk enclosure 2 red cable Network connections Each of the two servers has eight network adapters One of the adapters Cluster Internal is already connected to the corresponding adapter on the second node This is done through an internal switch located in the Mezz B slot in the rear of the enclosure 5 Figure 6 12 Installing the storage system ...

Страница 13: ...rk infrastructure Each adapter is labeled according to a suggested use for example 1 GbE Public 1 but you may rename the adapters in later configuration steps and use them in a way best suited to your environment In the network infrastructure that connects the cluster nodes avoid having single points of failure One way to do this is to have at least two distinct networks The HP X5000 G2 already pr...

Страница 14: ... because you can always add more networks after the system has been deployed The Enclosure Manager and iLO port 6 Figure 6 page 13 provides for a connection from your network infrastructure to the Enclosure Manager Unit EMU and to the iLO on each blade For ease of setup the EMU and each iLO processor have been assigned static IP addresses in the factory You use these addresses to make an initial c...

Страница 15: ...ure the networking properties for the local system a Open Control Panel select Network Sharing Center or Network Connections and navigate to Local Area Connections b Select Properties Internet Protocol and then select Properties c If Use the following IP address is selected record values for the following items and restore them after completing the EMU and iLO setup IP address Subnet mask Default ...

Страница 16: ...ge the administrator password To do so select User Administration under Administration in the iLO management interface b Configure the network as required for your environment Select Network under Administration in the iLO management interface You can either enable DHCP or edit the IP address details and enter site specific network settings Click Apply to save your settings c Repeat the process on...

Страница 17: ... Rack name EMU password located on the tear away label on the back of the server blade see Figure 10 page 17 IP addressing method To change the static IP address type the command set ipconfig static at the command line prompt and follow the instructions To change the EMU addressing to DHCP type set ipconfig dhcp at the command line prompt Figure 10 Tear away label location Example 1 Setting attrib...

Страница 18: ... the configuration a Connect the EMU port to the appropriate switch VLAN subnet b Log in to the EMU using ssh and the newly assigned EMU name and validate connectivity It is assumed that the EMU name is in the DNS Example 2 Verifying connectivity CustomerEMU dnsName show server list all Bay iLO Name iLO IP Address Status Power UID 1 ILOMXQ0110FJ9 16 78 90 51 OK On Off 2 ILOMXQ0110FHU 16 78 90 113 ...

Страница 19: ...r cable and monitor power cable Regardless of which access method you use perform the configuration from only one of the server blades The server blade you choose for configuration will be designated the first node and the other server blade will be designated the second node Figure 1 1 Keyboard mouse and monitor 1 Storage system enclosure 2 Monitor 3 Keyboard USB 4 Mouse USB NOTE The keyboard mou...

Страница 20: ... two nodes You will find instructions for this if needed in the online help of the Initial Configuration Tasks ICT Completing initial configuration After the servers reboot continue the configuration using the first node A default administrator password HPinvent has been set and this is used to log on automatically Leave this administrator password unchanged until you are prompted for a new passwo...

Страница 21: ... use Use the guidelines below as an aid in making configuration choices Network teaming Network teaming is a common use of multiple network adapters Teaming is used to increase available network bandwidth and provide fault tolerance Teaming can be across multiple ports in the same network adapter or across network adapters Multi home Distributing network workload across multiple network adapters i...

Страница 22: ...stem logs If you are unable to resolve a storage system operation issue after using the various options contact HP Support You must provide your SAID and your warranty and entitlement labels See Obtaining the Service Agreement ID page 54 and Locating the storage system warranty entitlement label page 54 Using notification alerts When you receive an alert open the System Manager described in Using ...

Страница 23: ...e 13 Configuring Alerts and Email 4 Do one of the following Select New to create a profile Select Copy or Edit to modify an existing profile The Alert Settings window appears Configuring Alerts and Email 23 ...

Страница 24: ...pany com Alerts Severity Select the severity for which you want to receive alerts You will also receive alerts for any severity higher than the one you select Select All to receive alerts for all severities Components Alerts Select the components for which you want to receive alerts or select All to receive alerts for all components 6 To test the ability for the recipient to receive email alerts c...

Страница 25: ...elect Properties to display the SNMP Service properties d Select the Security tab and specify the following items The external hosts that may use the SNMP protocol The SNMP Community string HP recommends that you use something other than the typical Public string IMPORTANT Configure HP SIM security to prevent the SIM management server from gaining access to SNMP The SNMP trap function in the stora...

Страница 26: ...ement Homepage Software A list of documents and advisories is displayed To view SMH user guides select User Guide Starting the System Management Homepage application To start the application double click the HP System Management Homepage desktop shortcut or enter https hostname 2381 in Internet Explorer The hostname can be localhost or the IP address of the server you want to monitor To log into S...

Страница 27: ...bapp sets the value of the Overall System Health Status icon by using a predefined heuristic If no webapp can determine the status the worst possible status is displayed in the Component Status Summary section Component Status summary The Component Status Summary section displays links to all subsystems that have a critical major minor or warning status If there are no critical major minor or warn...

Страница 28: ...of the other items in the Enclosure Information section can be displayed The enclosure I O ports are numbered from 1 to 8 in the SMH Figure 17 I O module These numbers correspond to the I O modules in the enclosure bays Figure 18 I O module bays 5 PCIe module 1 LOM module 6 PCIe module 2 LOM module 7 SAS I O module 3 MEZZ module 8 SAS I O module 4 Intraconnect internal switch Network This section ...

Страница 29: ...oller to view its type status firmware version and serial number Logical Drives A list of logical drives associated with the controller appears in the left panel tree view Select one of the logical drive entries to display the status of the drive fault tolerance RAID level and capacity volume size A link to the logical drive storage pool is also displayed Storage Pools A list of storage pools asso...

Страница 30: ... use the System Manager which has been preinstalled and configured use Remote Desktop or iLO to access the server blade Click the Server Manager icon located in the taskbar to the right of the Start button or select Start Administrative Tools Server Manager When Server Manager appears select System Manger in the left navigation pane To troubleshoot using the System Manager 1 Open the System Manage...

Страница 31: ...e logged in to If a problem is reported in the System section you should check the Hardware Status tab on each server blade NOTE If the System Manager shows that a LUN has an error open the System Management Homepage and determine whether the LUN is degraded due to a disk failure If so also use the System Management Homepage to determine which disk needs to be replaced Using the System Manager 31 ...

Страница 32: ...t to the Internet to identify new firmware you must periodically check the HP support web page and download new firmware when available Be sure to check the Firmware tab on each server blade Some firmware updates must be made on both server blades IMPORTANT If a firmware update requires a reboot you must reboot your storage system manually For more information about firmware updates see Upgrading ...

Страница 33: ...report can be used select the Run Quick Report Only option A quick report contains less information but is created in much less time It may contain all the necessary information HP support needs 2 Click Generate Support File A license agreement window is displayed 3 Select Yes to accept the license The report generation process begins It may take up to 45 minutes to create the reports When the pro...

Страница 34: ...ation on some status indicators you can use the EMU CLI SHOW commands described in Managing the EMU page 131 Figure 24 Server blade LEDs Table 2 Server blade LEDs status Status Description Item Blue Needs service check UID LED 1 Blue flashing remote management remote console in use via iLO OFF No remote management Green Normal Health LED 2 Flashing Booting 34 Monitoring and troubleshooting the sto...

Страница 35: ...ently active Hard drive LEDs 1 Flashing irregularly green The drive is online and it is operating normally Normal mode UID LED is solid Flashing green 1 Hz Do not remove the drive Removing the drive may terminate the current operation and cause data loss The drive is rebuilding or it is part of an array that is undergoing expansion logical drive extension a stripe size migration or RAID migration ...

Страница 36: ...lue or off When on it can be steady or blinking Used only for unit identification To set the LED use the following CLI command SET ENCLOSURE UID ON OFF SLOW FAST Chassis UID LED 4 OFF Enclosure is functioning normally NOTE All these LEDs are off if the enclosure has power but is turned off see Table 1 1 page 40 Then only the equivalent Chassis LEDs 2 3 4 on the rear Power Pod show status Figure 26...

Страница 37: ... is in a predictive failure state and Drive is not failed and Drive is not selected Blinking alternate amber blue 1Hz 50 duty cycle Drive Failed or Drive is in a predictive failure state and Drive is selected NOTE Spare drives are only used when a disk drive fails Until a spare drive is used it remains offline and its LEDs will remain off Figure 27 1210m Cache module controller LEDs Table 5 1210m ...

Страница 38: ...t causes EM fault LED 2 The health LED is only green and is either on Healthy or off Power off or Faulted EM health LED 3 LEDs are off when the enclosure is powered off Figure 29 HP 2 port 1 GB Ethernet I O modules LEDs Table 7 HP 2 port 1 GB Ethernet I O modules LEDs status Status Description Item Solid green when module health is good Module health LED 1 OFF when module has failed Solid amber wh...

Страница 39: ...n module has failed Module fault LED 2 OFF when module health is good LEDs are off when enclosure is powered off Figure 31 HP 1 GB intraconnect module LEDs Table 9 HP 1 GB intraconnect module LEDs status Status Description Item Solid green when module health is good Module health LED 1 OFF when module has failed Solid amber when module has failed Module fault LED 2 OFF when module health is good L...

Страница 40: ...ches and indicator LEDs Table 1 1 Chassis switches and indicator LEDs status Status Description Item Solid blue Requires service check UID 1 Solid green when system health is good Chassis health 2 OFF if a module or component in the system has failed Flashing amber if a module or component in the system has failed NOTE The amber chassis fault LED flashes if any component fault is detected by the S...

Страница 41: ...SAS I O module LEDs status Status Description Item Green Healthy SAS Port 1 1 2 Amber Issue Green Healthy SAS Port 2 3 4 Amber Issue Green Healthy Overall I O module status 5 6 Amber Issue Green Healthy SAS Port 3 7 8 Amber Issue Green Healthy SAS Port 4 9 10 Amber Issue If there is anything connected to a connector the corresponding green LED is on and blinks off with activity If there is nothing...

Страница 42: ...ot be lit unless enclosure power is on and its state depends upon signals from one of the SAS I O modules To troubleshoot a degraded fan you can use the EMU CLI commands SHOW ENCLOSURE STATUS and SHOW ENCLOSURE FAN ALL described in Managing the EMU page 131 EMU CLI SHOW commands Use the EMU CLI SHOW commands described in Managing the EMU page 131 to obtain additional information about component st...

Страница 43: ...the DNS server has not been set up to allow for updates from external clients To fix this issue The cluster IP address on a cluster network resource cannot resolve the DNS name or update the DNS name correctly causing the network resource to appear offline or with a warning message 1 Log in to the Active Directory Domain Services with your Domain Admins Administrator or Security Group access 2 Go ...

Страница 44: ...anually restart the node that was restarted or affected a cluster node is rebooted and rejoins the cluster The network interface is still Manually disable or enable the NIC on the affected cluster node that is causing the issue under Network Connections usable for communications to other nodes it is only the communications between the cluster nodes that is affected The cluster interface status wil...

Страница 45: ... the SAS I O module firmware again If the second update is unsuccessful review the log file for more information On rare occasions an update to the SAS I O module firmware may result in the following message Flash failed for xxxx half of SAS I O Module Check log file yyyy for more information where xxxx is internal or external and yyyy is the path and name of the log file Identify and reseat the S...

Страница 46: ...gs may cause your iLO sessions to disconnect administrator and belongs to the administrator group on each node The User Access Control system prevents the application from running on the second node No prompt is displayed to the user to allow execution on the second node Delete existing LUNs using either the Delete a Volume or Create a Witness Disk wizard after installing the System Recovery image...

Страница 47: ... Right click My Computer Manage Services and Applications b Right click WMI Control c Click Properties d Select the Security tab e Select the namespace f Click the Security button and enable the following permissions for the user Execute Methods Full Write Partial Write Provider Write Enable Account Remote Enable Read Security Edit Security 3 Click Apply and then click OK twice Using Storage Viewe...

Страница 48: ...You can also view details about each drive bay location ID serial number size health and model number In the lower part of the tool you can view volume information related to the drive 48 Monitoring and troubleshooting the storage system ...

Страница 49: ...uct or component Manuals Provides the latest user documentation applicable to the product or component User guides can be a useful source for troubleshooting information For most storage system hardware platforms the following ProLiant server manuals may be useful for troubleshooting assistance HP ProLiant Server User Guide or HP ProLiant Server Maintenance and Service Guide These guides contain s...

Страница 50: ...ble in your country The software is available in two variants HP Insight Remote Support Standard This software supports server and storage devices and is optimized for environments with 1 to 50 servers Ideal for customers who can benefit from pronotification but do not need proservice delivery and integration with a management platform HP Insight Remote Support Advanced This software provides comp...

Страница 51: ...guration and usage documentation visit the HP Management Packs for Microsoft Systems Center site at www hp com go storageworks scom2007 Windows Recovery Environment You can use Windows Recovery Environment to help diagnose and recover from operating system errors which may prevent Windows from booting To use Windows Recovery Environment to perform a system recovery see Restoring the system with Wi...

Страница 52: ...lp fix problems starting Windows Select an operating system to repair Restore your computer using a system image that you created earlier 6 Click Cancel until the Choose a recovery tool window opens Figure 38 System recovery options 7 Click Startup Repair The utility automatically attempts to repair the system image startup process It also attempts to repair the errors If the errors cannot be repa...

Страница 53: ...ard input method which is based on your location for example select US for United States and click Next 5 Select either of the following options it does not matter which option is selected and click Next Use recovery tools that can help fix problems starting Windows Select an operating system to repair Restore your computer using a system image that you created earlier 6 Click Cancel until the Cho...

Страница 54: ...es that the LUNs are now in the Enabled state Obtaining the Service Agreement ID Obtain the SAID from your service contract agreement and keep it in a secure location You must provide it when you contact HP Support Locating the storage system warranty entitlement label You must locate and identify the serial number and product number for the storage system components to obtain service under the wa...

Страница 55: ...ownload and install specific security updates as needed If your maintenance policy is to only update servers to current and tested versions of drivers firmware and software install the services releases when they are available If your maintenance policy allows you to update servers to current versions of drivers firmware and software that have not been tested with the storage system you can go to ...

Страница 56: ... name number box and click Search 4 Select your X5000 G2 product select the operating system and then select the service release 5 Follow the instructions included with the service release for installation Upgrading a component s firmware To determine if a component requires a firmware upgrade IMPORTANT Remember the following You must complete these steps on each server HP recommends that you comp...

Страница 57: ...aded Figure 43 page 58 The list of components can include Integrated Lights Out iLO HP 1210m controller System ROM I24 for the server blade Power Management controller firmware c Class blades Smart Array HP P410i Blade HDD controller Enclosure Manager Unit EMU External half of the SAS I O module Internal half of the SAS I O module I O module on an external disk enclosure Hard disk drives various m...

Страница 58: ...ponents such as hard drives the upgrade takes more time 6 Reboot the server blade from the Start menu if needed A message appears on the Firmware tab to alert you if a reboot is required after each component firmware upgrade After the upgrade completes the Firmware Status changes from Firmware updates recommended to A reboot is required NOTE If a reboot is not required after the component firmware...

Страница 59: ...e 1 1 Push the other server blade back into the enclosure 12 Reconnect the disk enclosures 13 Power on the HP X5000 G2 enclosure and both server blades 14 Verify that the 1210m controller firmware in both server blades is current Resolving errors after a disk drive firmware upgrade If after upgrading disk drive firmware on the storage system and rebooting the storage system the System Manager indi...

Страница 60: ...nent removal and replacement instructions in Removing and replacing hardware components page 61 For example to replace the HP 1 GB Ethernet I O module with a 10 GB module follow the instructions in Removing and replacing the HP Ethernet I O module page 78 If you need to shut down a server blade or the storage system to replace a component follow the instructions in Powering the storage system off ...

Страница 61: ...onents must be installed for the enclosure to cool properly If a component fails leave it in place in the enclosure until a new component is available for installation IMPORTANT Be sure to unpack the replacement part before you remove the existing component During replacement of the failed component HP recommends waiting until periods of low system activity to replace a component For all hot warm ...

Страница 62: ... order the part directly from HP and repair the product yourself or you can request that HP repair the product If you request repair from HP you may be charged for the repair depending on the product warranty No CSR The replaceable part is not available for self repair For assistance contact an HP authorized service provider For more information about CSR contact your local service provider For No...

Страница 63: ...Figure 44 Exploded view of the system Table 14 page 64 lists the CSR replaceable parts for the system Replaceable parts 63 ...

Страница 64: ...tory 631 1 12 001 Enclosure Manager module 10 Cold No 631 1 16 001 Server blade backplane 1 1 Cold No 631 129 001 Server airflow baffle 12 Cold No 631 130 001 Coil power assembly 13 Cold Optional 631 1 18 001 Drive drawer bezel LFF 14 Cold Optional 631 124 001 Drive drawer bezel SFF Not shown Cold Optional 631 126 001 LFF LED display board 15 Cold Optional 631 125 001 SFF LED display board Not sho...

Страница 65: ...25 2 5 inch disk drives Disks in disk enclosures Hot warm and cold swap components Hot or warm swapping a component means removing and replacing it while the main power is still on Cold swapping means removing and replacing the component while the main power is off Port purple colored handles on components like the fan module indicate the component is hot swappable IMPORTANT Remove and replace com...

Страница 66: ...r operation After replacing a system component check the following to verify that the component is operating properly If applicable verify that the green LED is lit continuously or blinking If not try reseating the component From the System Manager navigate to the Hardware Status and System Summary tabs to confirm the component failure alert no longer appears The status should be Good Wait times f...

Страница 67: ...e drives to ensure you replace the drives in the correct order Figure 46 Hard drive labeling 3 Remove all hard drives WARNING Carefully check the drive labels provided with the replacement board and then install the hard drives in the same slots from which you removed them If the drives are not installed in the correct slots the system might fail 4 Push the hard drive drawer back into the system e...

Страница 68: ...r 3 Figure 47 Extending the hard drive drawer 4 Replace all hard drives IMPORTANT Install the hard drives in the same slots from which you removed them or the system might fail Use the drive labels to ensure that you replace the drives in the correct order 5 Push the hard drive drawer back into the system enclosure 6 Plug in all cables at the back of the system enclosure and ensure that all cables...

Страница 69: ...Replacing the server interposer board 1 With the release handle open align the server interposer board with the alignment pins 1 Figure 49 page 69 and then close the server interposer release mechanism 2 Figure 49 page 69 NOTE Remember to move the server backplane power cable out of the way of the alignment pins Figure 49 Replacing the server interposer board 2 Reinstall the top back panel 3 Repla...

Страница 70: ... the latch to slide the top back panel off 5 Remove all modules from the back of the enclosure NOTE Make a note of all module locations so they can be placed back into their original locations 6 Open the release handle 1 Figure 50 page 70 and pull up to remove the server interposer board 2 Figure 50 page 70 NOTE This step may require significant force to accomplish Figure 50 Removing the server in...

Страница 71: ...he server blade airflow baffle from inside the enclosure Figure 53 page 71 Figure 53 Removing the server blade airflow baffle 1 1 Unplug the power cable from the server blade midplane 1 Figure 54 page 71 and then unplug the rear UID PCA from the midplane board 2 Figure 54 Unplugging the power cable and the UID PCA Removing and replacing the midplane board 71 ...

Страница 72: ...replacement midplane board a Push the captive locking pin into the midplane board 2 b Tighten the two thumbscrews holding the midplane board in place 3 Figure 56 Installing the midplane board 3 Plug the rear UID PCA into the midplane board 4 Plug the power cable into the server blade midplane 5 Partially insert the drive drawer 6 Plug the coil power plug into the midplane board 7 Reattach the coil...

Страница 73: ...routed down the side of the rack system components and indicators are easily visible and accessible Removing a SAS cable Remove the SAS cable that connects the system SAS I O module to the disk enclosure Replacing a SAS cable 1 Connect the SAS cable between the system SAS I O module and the disk enclosure 2 Verify that the replacement SAS cable is working properly by checking the associated LED st...

Страница 74: ... NOTE You may need to use significant force to accomplish this task Figure 58 Replacing the SAS I O module 2 Plug in all cables to the SAS I O module IMPORTANT You must install the SAS I O cables in the same slots from which they were removed or the system might fail 3 Verify that the replacement SAS I O module is working properly by checking the overall module status LED SAS I O module LEDs statu...

Страница 75: ...ir flow within the enclosure Both fan modules must be installed for the enclosure to cool properly The fan modules are not redundant to each other and each module cools a different half of the enclosure If a single fan module fails leave it in place in the enclosure until a new fan is available to install The fan modules have some built in redundancy to keep operating until a replacement can be ma...

Страница 76: ...ions Removing and replacing the power UID button assembly Removing the power UID button assembly 1 Power off the system as described in Powering the storage system off and on page 60 2 Remove the enclosure from the rack as described in Removing the system enclosure from the rack page 67 3 Remove the top back panel by pressing the panel release button and lifting the latch to slide the top back pan...

Страница 77: ...2 c Plug the cable into the power UID button assembly 3 Figure 63 Replacing the power UID button assembly 2 Push the hard drive drawer back in the system enclosure 3 Replace the hard drive fan module 4 Replace the top back panel 5 Replace the enclosure as described in Inserting the system enclosure into the rack page 68 Removing and replacing the power supply Removing the power supply 1 Verify the...

Страница 78: ...led component as described in Verifying component failure page 66 2 Label the cables and then unplug all cables from the HP Ethernet I O module 3 Press the module release mechanism to the right 1 Figure 64 page 78 and then remove the failed module 2 Figure 64 Removing the HP Ethernet I O module Replacing the HP Ethernet I O module 1 Insert the replacement HP Ethernet I O module Figure 65 page 78 F...

Страница 79: ...en the other server so that both servers are not turned off at the same time 3 Power off the appropriate server blade associated with the PCIe module that is being removed Server 1 is the top server and the PCIe module is on the left when looking from the back Server 2 is the bottom server and the PCIe module is on the right when looking from the back CAUTION Be sure to power off the server before...

Страница 80: ... module 1 Install the PCIe card in the replacement module 1 Figure 68 page 80 replace the bracket 2 and then reinsert the two screws into the bracket of the replacement module 3 Figure 68 Installing the PCIe card 2 Insert the replacement PCIe module into the system 1 Figure 69 page 81 and lock the release lever 2 NOTE The PCIe module should be inserted with the lever in the open position 80 Removi...

Страница 81: ... the associated LED status 6 Confirm that the system has resumed normal operations Removing and replacing the EMU module Removing the EMU module 1 Verify the failed component as described in Verifying component failure page 66 2 Unplug any cables from the EMU module 3 Press the EMU module release lever to the right 1 Figure 70 page 81 and then remove the EMU module 2 Figure 70 Removing the EMU Rem...

Страница 82: ... Manager to boot Removing and replacing the server blade backplane Removing the server blade backplane 1 Verify the failed component as described in Verifying component failure page 66 2 Power off the system as described in Powering the storage system off and on page 60 3 Remove the enclosure from the rack as described in Removing the system enclosure from the rack page 67 4 Remove the top back pa...

Страница 83: ...oving the server blade backplane Replacing the server blade backplane 1 Complete the following Figure 73 page 83 a Install the replacement server blade backplane 1 b Replace the screw 2 c Plug in the power cable 3 Figure 73 Installing the server blade backplane 2 Replace the large baffle on the bottom of the enclosure 3 Replace the small baffle beside the server blade backplane Removing and replac...

Страница 84: ...the midplane board page 72 Removing and replacing the server airflow baffle Removing the server airflow baffle 1 Power off the system as described in Powering the storage system off and on page 60 2 Remove the enclosure from the rack as described in Removing the system enclosure from the rack page 67 3 Remove the top back panel by pressing the release button and lifting the latch to slide the top ...

Страница 85: ...se Removing and replacing the front bezel full page 87 if you are not able to reach all of the screws due to the position of the system in the rack Removing the front bezel 1 Power off the system as described in Powering the storage system off and on page 60 2 Extend the hard drive drawer Figure 77 page 85 a Press upward on the release button on the hard drive drawer 1 b Pull the drawer handle dow...

Страница 86: ... making sure the bottom pins are aligned with the bottom holes 1 Figure 79 page 86 and replace the screws into the front bezel 2 NOTE There are two screws on the bottom four screws on the sides two on each side and two screws hidden behind the handle Figure 79 Replacing the front bezel 2 Push the drive drawer back into the system enclosure 3 Power on the system by pressing the power button ON 4 Ve...

Страница 87: ...as described in Removing the system enclosure from the rack page 67 3 Pull the hard drive handle down 90 degrees and slide out the hard drive drawer 4 Remove all eight screws from the front bezel and pull the handle down 90 degrees 1 Figure 80 page 87 Then lift the front bezel up and out to remove the front bezel 2 NOTE There are two screws on the bottom four screws on the sides two on each side a...

Страница 88: ...e system enclosure 4 Replace the enclosure as described in Inserting the system enclosure into the rack page 68 Removing and replacing the front LED display board in the rack standard NOTE If you are not able to access all of the screws due to the enclosure position in the rack use the full procedure instructions Removing the front LED display board in the rack 1 Verify the failed component as des...

Страница 89: ...y board 1 b Replace the four LED display board screws 2 c Reconnect the LED display board to the drive drawer 3 Figure 83 Installing the front LED display board 2 Replace the front bezel as described in Replacing the front bezel page 86 Removing and replacing the front LED display board full Removing the front LED display board full 1 Verify the failed component as described in Verifying component...

Страница 90: ...n the sides two on each side and two screws hidden behind the handle Figure 84 Removing the front bezel 6 Complete the following Figure 85 page 90 a Disconnect the LED display board from the drive backplane by pinching the ends of the LED display board cable together 1 b Remove the four screws from the LED display board 2 c Remove the LED display board from the drive drawer 3 Figure 85 Removing th...

Страница 91: ...ifying component failure page 66 2 Power off the system as described in Powering the storage system off and on page 60 3 Remove the enclosure as described in Removing the system enclosure from the rack page 67 4 Remove the top back panel by pressing the panel release button and lifting the latch to slide the top back panel off 5 Remove the hard drive fan module Figure 87 page 91 Figure 87 Removing...

Страница 92: ...ve drawer 1 b Pull the drawer handle down 90 degrees 2 c Extend the hard drive drawer 3 Figure 89 Extending the hard drive drawer NOTE You must repeat Step 8 for the remaining SAS I O module 9 Remove the plug bracket 2 Figure 90 page 93 from the coil power plug by removing the thumbscrew 1 92 Removing and replacing hardware components ...

Страница 93: ...r assembly 1 1 Press the release mechanism on the side rail 1 Figure 92 page 93 and then pull the hard drive drawer fully out of the enclosure 2 WARNING The hard drive drawer is heavy even after removing the hard drives Make sure the drawer is fully supported as you remove it from the enclosure Figure 92 Removing the drive drawer Removing and replacing a drive drawer 93 ...

Страница 94: ...awer partially back into the system enclosure until approximately two inches of the drawer is still out of the enclosure Figure 94 page 94 CAUTION Do not push the drive drawer completely into the enclosure You must first connect the power coil assembly to prevent damaging the power coil assembly Figure 94 Partially installing the drive drawer 4 Pull the cable slightly out of the coil power plug an...

Страница 95: ...ket 1 Figure 96 page 95 to the coil power plug and tighten the thumbscrew 2 Figure 96 Reattaching the plug bracket to the coil power plug 6 Push the drive drawer fully back into the system enclosure 1 Figure 97 page 96 and the handle back into place 2 Removing and replacing a drive drawer 95 ...

Страница 96: ... an approved SAS drive Do not replace the drive drawer hard drive during peak data transfer times Make sure the hard drive LED is off before you remove the hard drive Ensure that the capacity of the replacement drive is at least equal to the capacity of the original drive The capacity of the replacement drive should not be smaller NOTE After replacing the hard drives the approximate wait times for...

Страница 97: ...ending the hard drive drawer 3 Locate the failed hard drive NOTE Use the hard drive bay labels and the drive LED status an amber LED or no LEDs to help identify the failed drive 4 To remove the failed hard drive Figure 99 page 97 a Press the release button 1 b Pull the release lever 2 c Remove the hard drive 3 Figure 99 Remove the failed hard drive Removing and replacing the drive drawer hard driv...

Страница 98: ...the hard drive firmware version IMPORTANT You must reboot the storage solution after updating the drive drawer hard drive firmware Removing and replacing the drive drawer rails side or bottom NOTE Spare rail kits consist of rail pairs one side rail and two bottom drive drawer rails See Removing and replacing the enclosure rails page 103 for enclosure rail instructions Removing the drive drawer rai...

Страница 99: ...he hard drive drawer 3 Figure 101 Extending the hard drive drawer 5 Remove the plug bracket 2 Figure 102 page 99 from the coil power plug by removing the thumbscrew 1 Figure 102 Removing the plug bracket from the coil power plug 6 Unplug the coil power assembly from the midplane board Figure 103 page 100 Removing and replacing the drive drawer rails side or bottom 99 ...

Страница 100: ...page 100 and then pull the hard drive drawer fully out of the enclosure 2 WARNING The hard drive drawer is heavy even after removing the hard drives Make sure the drawer is fully supported as you remove it from the enclosure Figure 104 Removing the drive drawer 100 Removing and replacing hardware components ...

Страница 101: ...ntil the rail locks into place Figure 106 page 101 Figure 106 Installing the drive drawer rails 2 Align the replacement drive drawer rail with the three enclosure rails and then push the drive drawer partially back into the system enclosure so that approximately two inches of the drawer is still out of the enclosure Figure 107 page 102 CAUTION Do not push the drive drawer completely into the enclo...

Страница 102: ...oil power plug and connect it to the midplane board Figure 108 page 102 Figure 108 Connecting the coil power assembly to the midplane board 4 Reattach the plug bracket 1 Figure 109 page 103 to the coil power plug and tighten the thumbscrew 2 102 Removing and replacing hardware components ...

Страница 103: ...tem enclosure 6 Replace the top back panel 7 Replace the enclosure as described in Inserting the system enclosure into the rack page 68 Removing and replacing the enclosure rails Removing the enclosure rails 1 Power off the system as described in Powering the storage system off and on page 60 2 Remove the enclosure as described in Removing the system enclosure from the rack page 67 Removing and re...

Страница 104: ...xtend the hard drive drawer 3 Figure 1 1 1 Extending the hard drive drawer 4 Remove the plug bracket 2 Figure 1 12 page 104 from the coil power plug by removing the thumbscrew 1 Figure 1 12 Removing the plug bracket from the coil power plug 5 Unplug the coil power assembly from the midplane board Figure 1 13 page 105 104 Removing and replacing hardware components ...

Страница 105: ...pull the hard drive drawer fully out of the enclosure 2 Figure 1 14 Removing the drive drawer 7 Lift the release mechanism on the rail side or bottom 1 Figure 1 15 page 105 and then push the rail back and up to release and remove the rail 2 Figure 1 15 Removing the enclosure rails Removing and replacing the enclosure rails 105 ...

Страница 106: ...artially back into the system enclosure so that approximately two inches of the drawer is still out of the enclosure Figure 1 17 page 106 CAUTION Do not push the drive drawer completely into the enclosure You must first connect the power coil assembly to prevent damaging the power coil assembly Figure 1 17 Partially installing the drive drawer 3 Pull the cable slightly out of the coil power plug a...

Страница 107: ... Figure 1 19 page 107 to the coil power plug and tighten the thumbscrew 2 Figure 1 19 Reattaching the plug bracket to the coil power plug 5 Push the drive drawer fully back into the system enclosure 1 Figure 120 page 108 and the handle back into place 2 Removing and replacing the enclosure rails 107 ...

Страница 108: ...server blade release lever to lift or carry the server blade Always support the weight of the server blade by handling the chassis directly Improper use can damage the release lever and the server blade 1 Verify the failed component as described in Verifying component failure page 66 2 Power off the appropriate server blade by clicking Start and then select Shut Down 3 Remove the server blade Figu...

Страница 109: ...ing can cause ESD damage Replacing the server blade 1 Install the server blade 1 Figure 122 page 109 and then push the handle into place with the handle open 2 Figure 122 Replacing the server blade 2 Power on the server blade 3 Confirm that the system has resumed normal operations Removing and replacing the server blade hard drive Removing the server blade hard drive 1 Verify the failed component ...

Страница 110: ...e hard drive Figure 124 page 110 a Insert the replacement hard drive with the lever in the open position 1 b Push the release lever into place 2 Figure 124 Installing the hard drive 2 Verify that the server blade hard drive is working properly by checking the associated LED status NOTE This may require a wait time of less than 15 seconds for the LED status to appear 3 Confirm that the system has r...

Страница 111: ...ton on the access panel and slide the access panel to the left to remove it 7 The original cache module is connected to a capacitor pack so observe the cache module LEDs If the amber LED is solid data transfer to the flash device on the cache module is in progress Do not remove the cache module until the amber LED is off and then continue with the next step If the amber LED is not lit proceed to t...

Страница 112: ...ler card 3 are also shown Figure 127 Removing the capacitor pack NOTE Be sure to first remove the capacitor pack bracket 10 Loosen the two captive screws and remove the 1210m controller card Figure 128 page 112 Figure 128 Removing the controller card 1 12 Removing and replacing hardware components ...

Страница 113: ...e replacement 1210m controller is running current firmware see Upgrading a component s firmware page 56 NOTE You must reboot the storage solution after updating firmware on the 1210m controller because both controllers must be updated at the same time Removing and replacing the 1210m cache module Removing the 1210m cache module WARNING Wear gloves or use care when removing the capacitor pack to av...

Страница 114: ... progress Do not remove the 1210m cache until the amber LED is off and then continue with the next step If the amber 1210m cache LED is not lit proceed to the next step 7 Open the ejector latches 1 Figure 131 page 114 on each side of the 1210m cache module slot Typically opening the ejector latches ejects the cache module automatically If the module does not eject automatically after you open the ...

Страница 115: ...9 Disconnect the capacitor pack cable from the connector on the top of the cache module Figure 133 page 115 Figure 133 Disconnecting the capacitor pack cable Replacing the cache module 1 Connect the capacitor pack cable to the replacement cache module Removing and replacing the 1210m controller board components 1 15 ...

Страница 116: ...capacitor pack WARNING Wear gloves or use care when removing the capacitor pack to avoid physical injury CAUTION ESD can damage electronic components Be sure you are properly grounded before performing this procedure 1 Back up all data 2 Close all applications 3 Power off the server blade 4 Remove the server blade Figure 135 page 116 a Push the button to release the handle 1 b Pull the handle towa...

Страница 117: ...tches 1 Figure 136 page 117 on each side of the cache module slot Typically opening the ejector latches ejects the cache module automatically If the module does not eject automatically after you open the ejector latches remove the cache module 2 by grasping only the edges Figure 136 Removing the cache module 8 Remove the cache module 1 Figure 137 page 117 from the controller card 3 and the capacit...

Страница 118: ... pack you might see a POST message during reboot indicating that the array accelerator cache is disabled temporarily This behavior is normal because the new capacitor pack is likely to have a low charge The controller operates properly while the capacitor pack is recharging although the performance advantage of the array accelerator is absent You do not need to take any action because the recharge...

Страница 119: ... LED is off and then continue with the next step If the amber LED is not lit proceed to the next step 7 Loosen the three captive screws and remove the Mezzanine NIC Replacing the Mezzanine NIC To replace the Mezzanine NIC 1 Install the Mezzanine NIC press down on the connector to seat the board 1 Figure 140 page 119 and then tighten the captive screws 2 Figure 140 Installing the Mezzanine NIC 2 Re...

Страница 120: ... ORCA utility to delete logical drives For more information about ORCA see the Configuring Arrays on HP Smart Array Controllers Reference Guide which is available at http www hp com support manuals Under servers select Server Management and then select HP Smart Array Advanced Pack Software under Server Management Software Using a downloaded version of the System Recovery DVD If you have downloaded...

Страница 121: ...em Recovery image 2 Reboot the server blade to either the USB flash device or USB DVD drive The system BIOS attempts to boot to the USB device first by default Watch the monitor output during the boot as you may need to press a key to boot to the USB media NOTE If directly connected you may have to change the BIOS settings to ensure proper boot sequence If connected remotely you may have to change...

Страница 122: ...om the factory NOTE Although the recovery process restores the X5000 G2 to the factory version it does not restore the EMU and iLO address configuration to the factory defaults The EMU and iLO address configuration will be the same as it was prior to system recovery For each server follow the steps in Restoring the factory image with a DVD or USB flash device page 121 Once each server is displayin...

Страница 123: ...administrator account by pressing CTRL ALT DELETE If you are using an iLO remote console you must select the CTRL ALT DEL item from the Keyboard menu Select Change a password Enter the old password which is HPinvent then enter a new password 6 Select the time and date shown in the lower right corner of the task bar Click the Change date and time settings link Set the time zone of the server to be ...

Страница 124: ...ups to add any domain users to the Administrators group 9 In Server Manager select System Manager As shown in Figure 143 page 125 select Generate keys to authenticate with the EM When prompted enter the Administrator password for the Enclosure Manager In the X5520 Enclosure Settings window click the Generate Keys button to generate a key pair that will allow software on the server blade to communi...

Страница 125: ...m with Windows Recovery Environment NOTE To use Windows Recovery Environment you must have created a system backup with the Windows Server Backup utility 1 Do one of the following a For direct access attach the SUV cable supplied with the HP X5000 G2 Network Storage System to the port on the front of the server blade you want to recover Connect a monitor and USB mouse to the SUV cable Using the re...

Страница 126: ...RAID controller reconfigure the storage and recover using a backup image Continue with step 6 6 The System Recovery Options wizard scans the computer for a system image If it is unable to locate a system image the following message is displayed Figure 144 System image not found Either attach an external drive or insert a DVD that contains the backup files and click Retry If you want to recover fro...

Страница 127: ...ot interrupt the recovery process 12 Remove the directly connected DVD or flash device or remotely connected iLO virtual DVD or flash device from the server Restoring the system with Windows Recovery Environment 127 ...

Страница 128: ... versions firmware updates and other product resources Related information The following documents provide related information HP X5000 G2 Network Storage System Quick Start Guide HP 3U Storage System Rail Kit Installation Instructions HP X5000 G2 Network Storage System Release Notes To locate the storage system documents go to http www hp com go X5000 G2 and then click the support link You can al...

Страница 129: ...ent Extend leveling jacks to the floor Ensure that the full weight of the rack rests on the leveling jacks Install stabilizing feet on the rack In multiple rack installations fasten racks together securely Extend only one rack component at a time Racks can become unstable if more than one component is extended Rack stability 129 ...

Страница 130: ...that meets your needs To help us improve the documentation send any errors suggestions or comments to Documentation Feedback docsfeedback hp com Include the document title and part number version number or the URL when submitting your feedback 130 Documentation feedback ...

Страница 131: ...ame Do not include the symbols when entering the variable Used to separate input options Denotes a list of mandatory choices that must be made For example SET ENCLOSURE UID ON OFF must be in one of the following forms SET ENCLOSURE UID ON SET ENCLOSURE UID OFF Denotes an optional argument or set of characters Used to enclose command arguments that contain spaces NOTE All users logged into the CLI ...

Страница 132: ...r a password you are prompted to enter one Reserved user names are ALL case insensitive ADMINISTRATOR case insensitive switch1 switch2 switch3 switch4 switch5 switch6 switch7 switch8 daemon ldapuser nobody tbmuser_ vcmuser_ root and quire CLEAR SSHKEY Syntax CLEAR SSHKEY Description Disables a user account The system immediately logs out the user and prevents the user from logging in until the acc...

Страница 133: ...R ALL user name CERTIFICATE user name Description Removes the existing user specified by user name and or any certificate mapped to this user If the user is currently logged on their sessions are terminated Specifying ALL removes all users from the system except the default Administrator account The user is prompted for confirmation except in script mode Restrictions The user name is case sensitiv...

Страница 134: ...SER LIST user name Description Displays general user information and user rights which is always Admin for this firmware version Restrictions Does not show information for restricted user accounts only shows information for Administrator and other end user created accounts Since there are no bay or device access restrictions no information about bays being assigned is given SHOW SSHFINGERPRINT Syn...

Страница 135: ...ription Displays the current minimum password length and strong password settings Restrictions Time functions Because this small group of functions is used in conjunction with other groups it is separated as its own group SET DATE Syntax SET DATE MMDDhhmm Description Sets the enclosure date and time and optionally year and time zone Time is in a 24 hour format If the year or time zone parameters a...

Страница 136: ...c GMT 7 Etc GMT 1 If you leave the time zone century or year blank the current setting is reused Restrictions Date and time can only be set if NTP is disabled MM is an integer from 01 to 12 DD is an integer from 01 to 31 hh is an integer from 00 to 23 mm is an integer from 00 to 59 CC is an integer from 00 to 99 YY is an integer from 00 to 99 SET TIMEZONE Syntax SET TIMEZONE timezone Description S...

Страница 137: ... seconds Description Sets the polling interval for NTP servers The factory default polling interval is 720 seconds 12 minutes Restrictions The polling range is 60 86400 seconds 1 minute to 1 day NOTE EM 1 10 or later does not support this command SET NTP PRIMARY Syntax SET NTP PRIMARY host Description Sets the primary server used for synchronizing time date using the Network Time Protocol NTP host...

Страница 138: ...displaying of events that are triggered by status changes in the system Restrictions This command is specific to the current CLI session and must be issued for each CLI session to display events in that session The setting is not persistent Upon boot of the EM the event display is OFF SHOW ALL Syntax SHOW ALL Description Executes all SHOW commands in succession Restrictions To save the output you ...

Страница 139: ... that can be captured in the Enclosure Manager system log syslog and includes the cause and action for each event Restrictions None SHOW CSR FAST Syntax SHOW CSR FAST Description Displays all possible CSR events that can be captured in the Enclosure Manager system log syslog The output does not include the cause and action for each event like SHOW CSR ALL Restrictions None SHOW DATE Syntax SHOW DA...

Страница 140: ...NTS Syntax SHOW DISPLAY EVENTS Description Displays the current status of the display event setting Restrictions None SHOW EM Syntax SHOW EM INFO Description Displays information about the Enclosure Manager NOTE Hardware versions are A B C and so forth Aux info includes the change management SVN number and the health monitor PSoC firmware version number Both are needed occasionally in lab testing ...

Страница 141: ...losure and included options NOTE Some information such as Enclosure Name is user supplied and if never programmed has a default value The Solution part number serial number and name string are programmed in the factory depending on the software SKU that is pre installed These numbers and strings are not customer programmable but vary by solution SKU even if the hardware is the same type The soluti...

Страница 142: ...physical sensor temperature is displayed that is computed by iLO based on its thermal model and measurements from several sensors This model is transparent to the EM Until this calculation normalizes 0 is shown as the temperature for the blade so that right after power on of the enclosure it takes several seconds before a nonzero value is shown for the blades while other sensors are reported immed...

Страница 143: ...en set it is 0 SHOW SERVER TEMP Syntax SHOW SERVER TEMP ALL bay bay Description Displays temperature sensor information for the specified server or range of servers This data is provided by iLO to the EM which has no direct sensor access Restrictions The enclosure must be powered on otherwise iLO has no power and cannot sense temperature or send data to the EM Internet control The following comman...

Страница 144: ...d an IP address in the range starting from the number entered for ip address The keyword NONE can be used in place of ip address netmask or gateway to clear the IP address Restrictions ip address and netmask must be in the form where each ranges from 0 to 255 domain name is a string containing letters a z A Z digits 0 9 or a hyphen bay must be 1 or 2 SET EM GATEWAY Syntax SET EM GATEWAY bay number...

Страница 145: ...P static or link local The setting takes effect immediately If mode chosen is static other parameters are required see below Restrictions None SET IPCONFIG STATIC Syntax SET IPCONFIG STATIC ip address netmask gateway Description Configures the IP settings for the EM to static mode In selecting this mode the IP address and netmask are be set to ip address and netmask respectively These settings tak...

Страница 146: ...re power is removed This option can cause a server blade to lose data and possibly to become unstable Restrictions bay must be 1 or 2 Use of the FORCE option can cause a server blade to lose data and possibly to become unstable POWERON SERVER Syntax POWERON SERVER ALL bay bay NORMAL PXE HDD RBSU Description Power on the specified server Adding an optional boot argument forces the blade to ignore t...

Страница 147: ...f the UID LED on the specified servers Restrictions This command functions only if the enclosure power is already on NOTE Because the EMU hardware cannot determine if a blade is physically present unless enclosure power is on the EM reports the warning that the blade is not present if this command is used when enclosure power is off SET SERVER BOOT Syntax SET SERVER BOOT FIRST ONCE NORMAL HDD PXE ...

Страница 148: ...ettings in the ROM Based Setup Utility Restrictions This command functions only if the enclosure power is already on Because the EMU hardware cannot determine if a blade is physically present unless enclosure power is on the EM reports the warning that the blade is not present if this command is used when enclosure power is off SHOW SERVER INFO Syntax SHOW SERVER INFO ALL bay bay Description Displ...

Страница 149: ...e various enclosure control functions DOWNLOAD CONFIG Syntax DOWNLOAD CONFIG URL Description Downloads a previously saved configuration script file from a specific IP host then executes it This command should be used to recover configuration after replacement of a failed EMU Supported protocols are HTTP FTP and TFTP The URL should be formatted asprotocol host path file If your FTP server does not ...

Страница 150: ...wer button Restrictions None UPLOAD CONFIG Syntax UPLOAD CONFIG URL Description Uploads a script to the specified URL which duplicates the current runtime configuration Supported protocols are FTP and TFTP The URL should be formatted as protocol host path filename If your FTP server does not support anonymous logins you can specify a username and password within the URL formatted as ftp username p...

Страница 151: ...le displayed with SHOW ENCLOSURE INFO command and is provided to the StorageWorks 1200m HBA in the MEZZ2 slot of the server through the MEZZPOS CLP string The command takes effect immediately IMPORTANT Do not change the enclosure ID You will be unable to access the data volumes from the servers Restrictions id is a decimal integer from 0 to 99 SET ENCLOSURE NAME Syntax SET ENCLOSURE NAME enclosure...

Страница 152: ...iLOs are reset to force a refresh of the enclosure information passed to iLO Restrictions None SET RACK NAME Syntax SET RACK NAME rack name Description Sets the user defined string reported with SHOW RACK NAME command The system responds with confirmation of the change The default unset by user rack name is UnnamedRack Restrictions rack name must be 1 to 32 characters long and includes all alphanu...

Страница 153: ...M itself it does not delete the remote syslog if remote logging is enabled SHOW SYSLOG SERVER Syntax SHOW SYSLOG SERVER bay Description Displays the syslog for the specified server If the session is not in script mode the EM paged the display of the output to throttle output and give the user time to view the data iLO syslog data is formatted in XML Restrictions bay must be 1 or 2 This command can...

Страница 154: ...y functions if remote syslog is enabled SET REMOTE SYSLOG SERVER Syntax SET REMOTE SYSLOG SERVER IPv4 dns name Description Sets the IP address of a remote system log server Restrictions EM 1 0 only supports IPv4 Settings are not used unless remote system logging is enabled SET REMOTE SYSLOG PORT Syntax SET REMOTE SYSLOG PORT port Description Sets the UDP destination port for remote system logging ...

Страница 155: ...ansient context which has a state that can be explicitly controlled by the user This section describes commands for managing session state and behavior CLEAR SCREEN Syntax CLEAR SCREEN Description Clears the terminal screen Restrictions None CONNECT SERVER Syntax CONNECT SERVER bay Description Opens a Text Console session to the iLO specified by the server bay number Exit from the session with exi...

Страница 156: ...ackets should be replaced with the value indicated Restrictions None SET SCRIPT Syntax SET SCRIPT MODE ON OFF Description Sets script mode on or off script mode prevents commands from prompting for input or confirmation All actions are performed without confirmation Default values are used for any parameters that normally require user interaction This setting is only effective for the current CLI ...

Страница 157: ...ole number from 1 to 86400 NOTE Once the pause begins there is no way to continue the session before time runs out but you can always terminate the session from the client end and start another one Restrictions The seconds parameter can be any whole number from 1 to 86400 HISTORY Syntax HISTORY Description Shows the history of commands for the current session Restrictions None Using the Enclosure ...

Страница 158: ...s Reboot EM bE The EM LAN interface is not responding to the remote management software but is configured to do so or the EM has just been reconfigured and needs to be rebooted for the configuration to take effect To reboot the EM 1 Enter the menu mode using the Activate Button Menu page 158 2 Press the UP button one time The EM changes the display from _ _ to bE to indicate that menu choice 0 Reb...

Страница 159: ...P address assignment is handled dynamically To set a DHCP IP address 1 Enter the menu mode using the Activate Button Menu page 158 2 Press the UP button until the display changes from _ _ to dH 3 Press and hold the UP button for three seconds The EM flashes dH to acknowledge the selection 4 Release the UP button The system sets the EM to DHCP and exits the menu mode This event is also logged in th...

Страница 160: ...he other three octets of the EM IP address You can back up using the DOWN button 6 Press and hold the DOWN button for three seconds The EM flashes IP to acknowledge the selection and then exits the operation The system displays the Enclosure ID to indicate that the operation is complete Exit Button Menu Exit the main menu or any subfunction To exit the button menu Press and hold the DOWN button fo...

Страница 161: ...s in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user FCC rating label The FCC rating label on the device shows the classification A or B of the equipment Class B devices have an FCC logo or ID on the label Class A devices do not have an FCC logo or ID on the label After you determine the class of the device ...

Страница 162: ...nterference Causing Equipment Regulations Cet appareil numérique de la class A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada Class B equipment This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil numérique de la class B respecte toutes les exigences du Règlement sur le matériel brouilleur du ...

Страница 163: ...Japanese notices Japanese VCCI A notice Japanese VCCI B notice Japanese VCCI marking Japanese power cord statement Korean notices Class A equipment Class B equipment Japanese notices 163 ...

Страница 164: ...Taiwanese notices BSMI Class A notice Taiwan battery recycle statement Vietnamese notice 164 Regulatory compliance notices ...

Страница 165: ...re to hazardous radiation Do not try to open the module enclosure There are no user serviceable components inside Do not operate controls make adjustments or perform procedures to the laser device other than those specified herein Allow only HP Authorized Service technicians to repair the unit The Center for Devices and Radiological Health CDRH of the U S Food and Drug Administration implemented r...

Страница 166: ...German laser notice Italian laser notice Japanese laser notice 166 Regulatory compliance notices ...

Страница 167: ...means do not dispose of your product with your other household waste Instead you should protect human health and the environment by handing over your waste equipment to a designated collection point for the recycling of waste electrical and electronic equipment For more information please contact your household waste disposal service Recycling notices 167 ...

Страница 168: ...cí elektrického a elektronického vybavení Pro více informací kontaktujte společnost zabývající se sběrem a svozem domovního odpadu Danish recycling notice Bortskaffelse af brugt udstyr hos brugere i private hjem i EU Dette symbol betyder at produktet ikke må bortskaffes sammen med andet husholdningsaffald Du skal i stedet den menneskelige sundhed og miljøet ved at afl evere dit brugte udstyr på et...

Страница 169: ... au rebut d équipement par les utilisateurs privés dans l Union Européenne Ce symbole indique que vous ne devez pas jeter votre produit avec les ordures ménagères Il est de votre responsabilité de protéger la santé et l environnement et de vous débarrasser de votre équipement en le remettant à une déchetterie effectuant le recyclage des équipements électriques et électroniques Pour de plus amples ...

Страница 170: ...beszolgáltatásával megóvja az emberi egészséget és a környezetet További információt a helyi köztisztasági vállalattól kaphat Italian recycling notice Smaltimento di apparecchiature usate da parte di utenti privati nell Unione Europea Questo simbolo avvisa di non smaltire il prodotto con i normali rifi uti domestici Rispettare la salute umana e l ambiente conferendo l apparecchiatura dismessa a un...

Страница 171: ...tu elektrycznego i elektronicznego Więcej informacji można uzyskać od lokalnej firmy zajmującej wywozem nieczystości Portuguese recycling notice Descarte de equipamentos usados por utilizadores domésticos na União Europeia Este símbolo indica que não deve descartar o seu produto juntamente com os outros lixos domiciliares Ao invés disso deve proteger a saúde humana e o meio ambiente levando o seu ...

Страница 172: ...los residuos domésticos En lugar de ello debe evitar causar daños a la salud de las personas y al medio ambiente llevando los equipos que no utilice a un punto de recogida designado para el reciclaje de equipos eléctricos y electrónicos que ya no se utilizan Para obtener más información póngase en contacto con el servicio de recogida de residuos domésticos Swedish recycling notice Hantering av ele...

Страница 173: ...Battery replacement notices Dutch battery notice French battery notice Battery replacement notices 173 ...

Страница 174: ...German battery notice Italian battery notice 174 Regulatory compliance notices ...

Страница 175: ...Japanese battery notice Spanish battery notice Battery replacement notices 175 ...

Страница 176: ... ROM Based Setup Utility SAID Service Agreement Identifier SCOM Systems Center Operations Manager SIM Systems Insight Manager SKU Stock keeping unit SMH System Management Homepage TCO Total cost of ownership A financial estimate for determining economic value of an investment UID Unit identification WBEM Web Based Enterprise Management Witness Server A server used for high availability in conjunct...

Страница 177: ... CLI reference 131 configuring management processor 15 LED behavior 37 logging in 42 removing and replacing 81 using CLI SHOW commands for troubleshooting 42 enclosure rails removing and replacing 103 Ethernet I O module removing and replacing 78 European Union notice 162 Event Notifier configuring for proemail SMTP event notification 22 F factory image restoring the system 121 failure of componen...

Страница 178: ...ving and replacing 76 product number locating 9 R rack rails removing and replacing 108 Rack stability HP 129 recovering the system 120 system recovery DVD 120 USB flash drive 121 recycling notices 167 regulatory compliance Canadian notice 162 European Union notice 162 identification numbers 161 Japanese notices 163 Korean notices 163 laser 165 recycling notices 167 Taiwanese notices 164 Vietnames...

Страница 179: ... Taiwanese notices 164 technical support see Support websites troubleshooting tools 22 component LEDs 34 EMU CLI SHOW commands 42 Event Notifer 22 Insight Remote Support 50 Microsoft Systems Center Operations Manager SCOM 51 notification alerts 22 System Management Homepage 26 System Manager 30 U unpacking the X5000 G2 Network Storage System 9 updating system software and firmware 55 upgrading sys...