134
7 Tests and Error Messages
Error Message Summary
Error Message Summary
In the event of an error generated in POST (Power-On-Self-Test) during the
boot process, the Error Setup Manager gives access to one or more detected
errors. Each EMU error is displayed as a 4-digit code with an associated text
message on the monitor screen.
Further details can be accessed by pressing ENTER. A detailed description
of the reason for the failure and how to solve the problem is displayed. The
following examples give the different types of error categories.
Category #1:
If the error is only a warning (i.e. key stuck), the POST should prompt:
WARNING
1
00100
Keyboard Error
1.
After a time-out period of five seconds without any intervention, the system resumes to boot.
Category #2:
If the error is serious, the POST should prompt:
00xx
The BIOS has detected a serious problem that prevents your PC from booting
Press <Enter> to view more information about error