Fabric OS Commands
790
Fabric OS Version 3.1.x/4.1.x Reference Guide
Note:
There is a LINK table that stores 16 pairs of SID-DID address. Each of the
SID-DID pairs is named a LINK. This table is used for gathering statistics that match the
LINK.
Operands
This command has the following operands:
Example
To run a statistics counter test on a switch (V3.1.x example):
To run a statistics counter test on a switch (V4.1.x example):
Errors: V4.1.x
When it detects failure(s), the subtest may report one or more of the following
error messages:
DIAG-STSINIT
DIAG-STSNULL
DIAG-STSSID
DIAG-STSXMIT
DIAG-STSRCV
DIAG-STSFRMCNT
passcount
(V3.1.x only)
-passcnt count
(V4.1.x only)
Specify the number of times to perform this test. The default
value is 1. This operand is optional.
-ports itemlist
(V4.1.x only)
Specify a list of user ports to run the test. If omitted, all the
user ports in the switch will be assumed. See
itemlist
for more information about selecting ports. This operand is
optional.
switch:admin> statsTest
Running Statistics Cnt Test ... passed.
switch:admin>
switch:admin> statstest -passcnt 1 -ports 1/0-15
Running Statistics Counter Test ....... passed.
switch:admin>
Содержание StorageWorks MSA 2/8 - SAN Switch
Страница 41: ...aliasPurge 41 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also aliasJoin aliasShow fabricShow switchShow ...
Страница 82: ...Fabric OS Commands 82 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also chippropshow ptpropshow ...
Страница 178: ...Fabric OS Commands 178 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also setdbg ...
Страница 222: ...Fabric OS Commands 222 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also ipaddrset ipaddrshow ...
Страница 228: ...Fabric OS Commands 228 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also errNvLogSizeShow errSaveLvlShow errShow ...
Страница 251: ...fabstateshow 251 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fabstateclear fabportshow ...
Страница 258: ...Fabric OS Commands 258 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fanShow fanDisable ...
Страница 263: ...fashow 263 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fazonecreate fastatsshow ...
Страница 301: ...firmwarerestore 301 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also firmwareCommit firmwareDownload ...
Страница 315: ...fwClassInit 315 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwConfigReload fwConfigure fwShow ...
Страница 329: ...fwMailCfg 329 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwconfigure fwclassinit fwshow fwconfigreload ...
Страница 337: ...fwShow 337 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwClassInit fwConfigReload fwConfigure ...
Страница 375: ...interfaceShow 375 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portShow switchShow ...
Страница 411: ...logout 411 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also login ...
Страница 446: ...Fabric OS Commands 446 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also version ...
Страница 452: ...Fabric OS Commands 452 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsshow nsallshow nscamshow ...
Страница 455: ...nsaliasshow 455 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsshow nsallshow switchshow ...
Страница 462: ...Fabric OS Commands 462 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsAllShow switchShow ...
Страница 493: ...perfCfgClear 493 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgRestore perfCfgSave ...
Страница 495: ...perfCfgRestore 495 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgClear perfCfgSave ...
Страница 497: ...perfCfgSave 497 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgClear perfCfgRestore ...
Страница 518: ...Fabric OS Commands 518 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfAddEEMonitor ...
Страница 575: ...portLogDump 575 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portLogClear portLogShow uptime ...
Страница 578: ...Fabric OS Commands 578 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portLogClear portLogShow uptime ...
Страница 694: ...Fabric OS Commands 694 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also secfabricshow secmodedisable secmodeshow ...
Страница 811: ...switchDisable 811 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also switchEnable switchShow ...
Страница 823: ...switchShow 823 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also switchDisable switchEnable switchName ...
Страница 839: ...syslogdIpRemove 839 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also errShow syslogdIpAdd syslogdIpShow ...
Страница 849: ...timeout 849 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also None ...
Страница 878: ...Fabric OS Commands 878 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also configShow uRouteConfig uRouteShow ...
Страница 910: ...Fabric OS Commands for Licensed Products 910 Fabric OS Version 3 1 x 4 1 x Reference Guide ...