Fabric OS Commands
372
Fabric OS Version 3.1.x/4.1.x Reference Guide
masterPort
Port number of the trunk master port, if present, of the
trunk group this port is a part of.
defaultCost
The default cost of sending a frame over the ISL
connection to this interface.
cost
Cost of sending a frame over the ISL connected to this
interface. A value of 1000 indicates a 1 Gb/s link. A
value of 500 indicates a 2 Gb/s link.
delay
Conventional delay incurred by a frame transmitted on
this ISL. A fixed value required by the FSPF protocol.
lastScn
Type of the last State Change Notification received on
this interface.
lastScnTime
Time the last State Change Notification was received on
this interface.
upCount
Number of times this interface came up, with respect to
FSPF.
lastUpTime
Last time this interface came up.
downCount
Number of times this interface went down.
lastDownTime
Last time this interface went down.
downReason
Type of last State Change Notification that caused this
interface to go down.
iState
Current state of this interface. The state can be UP or
DOWN. An interface in DOWN state does not have an
allocated neighbor data structure and cannot be used to
route traffic to other switches.
state
Current state of this interface. This E_Port is used to route
traffic to other switches only if the state is “NB_ST_FULL.”
nghbCap
Neighbor capabilities. Should be 0.
nghbId
Domain ID of the neighbor (adjacent) switch.
idbNo
IDB number. Should be equal to portnumber
remPort
Port number on the remote switch connected to this port.
nflags
Internal FSPF flags.
initCount
Number of times this neighbor was initialized, without
the interface going down.
&dbRetransList
Pointer to the database retransmission list.
&lsrRetransList
Pointer to the Link State Records (LSR) retransmission list.
&lsrAckList
Pointer to the Link State Acknowledgements (LSA)
retransmission list.
Содержание StorageWorks MSA 2/8 - SAN Switch
Страница 41: ...aliasPurge 41 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also aliasJoin aliasShow fabricShow switchShow ...
Страница 82: ...Fabric OS Commands 82 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also chippropshow ptpropshow ...
Страница 178: ...Fabric OS Commands 178 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also setdbg ...
Страница 222: ...Fabric OS Commands 222 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also ipaddrset ipaddrshow ...
Страница 228: ...Fabric OS Commands 228 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also errNvLogSizeShow errSaveLvlShow errShow ...
Страница 251: ...fabstateshow 251 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fabstateclear fabportshow ...
Страница 258: ...Fabric OS Commands 258 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fanShow fanDisable ...
Страница 263: ...fashow 263 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fazonecreate fastatsshow ...
Страница 301: ...firmwarerestore 301 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also firmwareCommit firmwareDownload ...
Страница 315: ...fwClassInit 315 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwConfigReload fwConfigure fwShow ...
Страница 329: ...fwMailCfg 329 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwconfigure fwclassinit fwshow fwconfigreload ...
Страница 337: ...fwShow 337 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwClassInit fwConfigReload fwConfigure ...
Страница 375: ...interfaceShow 375 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portShow switchShow ...
Страница 411: ...logout 411 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also login ...
Страница 446: ...Fabric OS Commands 446 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also version ...
Страница 452: ...Fabric OS Commands 452 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsshow nsallshow nscamshow ...
Страница 455: ...nsaliasshow 455 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsshow nsallshow switchshow ...
Страница 462: ...Fabric OS Commands 462 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsAllShow switchShow ...
Страница 493: ...perfCfgClear 493 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgRestore perfCfgSave ...
Страница 495: ...perfCfgRestore 495 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgClear perfCfgSave ...
Страница 497: ...perfCfgSave 497 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgClear perfCfgRestore ...
Страница 518: ...Fabric OS Commands 518 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfAddEEMonitor ...
Страница 575: ...portLogDump 575 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portLogClear portLogShow uptime ...
Страница 578: ...Fabric OS Commands 578 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portLogClear portLogShow uptime ...
Страница 694: ...Fabric OS Commands 694 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also secfabricshow secmodedisable secmodeshow ...
Страница 811: ...switchDisable 811 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also switchEnable switchShow ...
Страница 823: ...switchShow 823 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also switchDisable switchEnable switchName ...
Страница 839: ...syslogdIpRemove 839 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also errShow syslogdIpAdd syslogdIpShow ...
Страница 849: ...timeout 849 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also None ...
Страница 878: ...Fabric OS Commands 878 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also configShow uRouteConfig uRouteShow ...
Страница 910: ...Fabric OS Commands for Licensed Products 910 Fabric OS Version 3 1 x 4 1 x Reference Guide ...