crossPortTest
165
Fabric OS Version 3.1.x/4.1.x Reference Guide
V3.1.x: SwitchEnable and SwitchDisabled Mode /
V4.1.x: SwitchOnline and SwitchOffline Mode
The
crossPortTest
command can be executed when the switch is
enabled/online or disabled/offline.
In SwitchEnabled/SwitchOnline mode (where the switch is enabled prior to
executing the
crossPortTest
command) only ports which are cable
loopbacked to ports in the same switch are tested. Ports connected outside of the
switch are ignored.
To run the
crossPortTest
command successfully the test must find at least
one port (lb_mode = 1, this is the default) or two ports (lb_mode = 0) cable
loopbacked to each other. If this criteria is not met, one of the following messages
is displayed:
Need at least one port(s) connected to run this test
Need at least two port(s) cross-connected to run this test
In SwitchDisabled/SwitchOffline mode (when the switch is disabled prior to
executing the
crossPortTest
command) all ports are assumed to be cable
loopbacked to different ports in the same switch. If one or more ports are not
connected, the test aborts.
The test determines which port is connected to which port transmitting frames. If
any ports are not properly connected (improperly seated SFPs or cables, bad SFPs
or cables, or improper connection or improper connection of SWL to LWL), the
following message is displayed:
One or more ports is not active, please double check fibres on
all ports.
V3.1.x: singlePortAlso Mode
The
singlePortAlso
mode is specified by executing
crossporttest
command with the
singleportalso
operand specified as a value of 1. For
example:
switch:admin> crossporttest 100, 1
In this mode,
crossporttest
enables a port to be cable loopbacked to itself
(port M is connected to port M) in addition to the cross connection supported (port
M is connected to port N). This can be used to isolate bad ports.
Содержание StorageWorks MSA 2/8 - SAN Switch
Страница 41: ...aliasPurge 41 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also aliasJoin aliasShow fabricShow switchShow ...
Страница 82: ...Fabric OS Commands 82 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also chippropshow ptpropshow ...
Страница 178: ...Fabric OS Commands 178 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also setdbg ...
Страница 222: ...Fabric OS Commands 222 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also ipaddrset ipaddrshow ...
Страница 228: ...Fabric OS Commands 228 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also errNvLogSizeShow errSaveLvlShow errShow ...
Страница 251: ...fabstateshow 251 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fabstateclear fabportshow ...
Страница 258: ...Fabric OS Commands 258 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fanShow fanDisable ...
Страница 263: ...fashow 263 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fazonecreate fastatsshow ...
Страница 301: ...firmwarerestore 301 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also firmwareCommit firmwareDownload ...
Страница 315: ...fwClassInit 315 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwConfigReload fwConfigure fwShow ...
Страница 329: ...fwMailCfg 329 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwconfigure fwclassinit fwshow fwconfigreload ...
Страница 337: ...fwShow 337 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwClassInit fwConfigReload fwConfigure ...
Страница 375: ...interfaceShow 375 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portShow switchShow ...
Страница 411: ...logout 411 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also login ...
Страница 446: ...Fabric OS Commands 446 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also version ...
Страница 452: ...Fabric OS Commands 452 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsshow nsallshow nscamshow ...
Страница 455: ...nsaliasshow 455 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsshow nsallshow switchshow ...
Страница 462: ...Fabric OS Commands 462 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsAllShow switchShow ...
Страница 493: ...perfCfgClear 493 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgRestore perfCfgSave ...
Страница 495: ...perfCfgRestore 495 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgClear perfCfgSave ...
Страница 497: ...perfCfgSave 497 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgClear perfCfgRestore ...
Страница 518: ...Fabric OS Commands 518 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfAddEEMonitor ...
Страница 575: ...portLogDump 575 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portLogClear portLogShow uptime ...
Страница 578: ...Fabric OS Commands 578 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portLogClear portLogShow uptime ...
Страница 694: ...Fabric OS Commands 694 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also secfabricshow secmodedisable secmodeshow ...
Страница 811: ...switchDisable 811 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also switchEnable switchShow ...
Страница 823: ...switchShow 823 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also switchDisable switchEnable switchName ...
Страница 839: ...syslogdIpRemove 839 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also errShow syslogdIpAdd syslogdIpShow ...
Страница 849: ...timeout 849 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also None ...
Страница 878: ...Fabric OS Commands 878 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also configShow uRouteConfig uRouteShow ...
Страница 910: ...Fabric OS Commands for Licensed Products 910 Fabric OS Version 3 1 x 4 1 x Reference Guide ...