secpolicyadd
703
Fabric OS Version 3.1.x/4.1.x Reference Guide
Add members to an existing policy.
Synopsis
secpolicyadd “name”, “member;member”
Availability
Admin
Release
V3.1.x and V4.1.x
Description
Use this command to add members to an existing access policy. The new members
must not already be members within the policy or the command fails.
Each policy corresponds to a management method. The list of members of a
policy acts as an access control list for that management method. When security is
first enabled using the
secmodeenable
command only the FCS_POLICY
exists. Before a policy is created, there is no enforcement for that management
method, that is, all access is granted. After a policy has been created and a
member has been added to the policy, that policy becomes closed to all access
except from included members. If all members are then deleted from the policy,
all access is denied for that management access method (the DCC_POLICY and
OPTIONS_POLICY are exceptions).
Note:
When security is enabled, this command can only be issued from the Primary
FCS switch. See “
Security Commands
” on page 941.
secpolicyadd
Содержание StorageWorks MSA 2/8 - SAN Switch
Страница 41: ...aliasPurge 41 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also aliasJoin aliasShow fabricShow switchShow ...
Страница 82: ...Fabric OS Commands 82 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also chippropshow ptpropshow ...
Страница 178: ...Fabric OS Commands 178 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also setdbg ...
Страница 222: ...Fabric OS Commands 222 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also ipaddrset ipaddrshow ...
Страница 228: ...Fabric OS Commands 228 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also errNvLogSizeShow errSaveLvlShow errShow ...
Страница 251: ...fabstateshow 251 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fabstateclear fabportshow ...
Страница 258: ...Fabric OS Commands 258 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fanShow fanDisable ...
Страница 263: ...fashow 263 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fazonecreate fastatsshow ...
Страница 301: ...firmwarerestore 301 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also firmwareCommit firmwareDownload ...
Страница 315: ...fwClassInit 315 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwConfigReload fwConfigure fwShow ...
Страница 329: ...fwMailCfg 329 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwconfigure fwclassinit fwshow fwconfigreload ...
Страница 337: ...fwShow 337 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwClassInit fwConfigReload fwConfigure ...
Страница 375: ...interfaceShow 375 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portShow switchShow ...
Страница 411: ...logout 411 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also login ...
Страница 446: ...Fabric OS Commands 446 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also version ...
Страница 452: ...Fabric OS Commands 452 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsshow nsallshow nscamshow ...
Страница 455: ...nsaliasshow 455 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsshow nsallshow switchshow ...
Страница 462: ...Fabric OS Commands 462 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsAllShow switchShow ...
Страница 493: ...perfCfgClear 493 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgRestore perfCfgSave ...
Страница 495: ...perfCfgRestore 495 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgClear perfCfgSave ...
Страница 497: ...perfCfgSave 497 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgClear perfCfgRestore ...
Страница 518: ...Fabric OS Commands 518 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfAddEEMonitor ...
Страница 575: ...portLogDump 575 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portLogClear portLogShow uptime ...
Страница 578: ...Fabric OS Commands 578 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portLogClear portLogShow uptime ...
Страница 694: ...Fabric OS Commands 694 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also secfabricshow secmodedisable secmodeshow ...
Страница 811: ...switchDisable 811 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also switchEnable switchShow ...
Страница 823: ...switchShow 823 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also switchDisable switchEnable switchName ...
Страница 839: ...syslogdIpRemove 839 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also errShow syslogdIpAdd syslogdIpShow ...
Страница 849: ...timeout 849 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also None ...
Страница 878: ...Fabric OS Commands 878 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also configShow uRouteConfig uRouteShow ...
Страница 910: ...Fabric OS Commands for Licensed Products 910 Fabric OS Version 3 1 x 4 1 x Reference Guide ...