![HP StorageWorks MSA 2/8 - SAN Switch Скачать руководство пользователя страница 517](http://html.mh-extra.com/html/hp/storageworks-msa-2-8-san-switch/storageworks-msa-2-8-san-switch_reference-manual_165663517.webp)
perfShowEEMonitor
517
Fabric OS Version 3.1.x/4.1.x Reference Guide
Example
To display end-to-end monitor frame traffic on blade 4 port 5 at an interval of
every 6 seconds:
To display EE monitors on blade 4 port 5:
Note:
If you do not specify an interval, the EE based monitor traffic count is displayed
in 64 bit format and is cumulative.
switch:admin> perfShowEEMonitor 4/5, 6
perfShowEEMonitor 4 1: Tx/Rx are # of bytes and crc is # of crc errors
0
1
2
3
4
------------- ------------- ------------- ------------- -------------
crc Tx Rx crc Tx Rx crc Tx Rx crc Tx Rx crc Tx Rx
============= ============= ============= ============= =============
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 53m 4.9m
0 53m 4.9m
0 53m 4.9m
0 53m 4.9m
0 53m 0
0 53m 4.4m
0 53m 4.4m
0 53m 4.4m
0 53m 4.4m
0 53m 0
0 53m 4.8m
0 53m 4.8m
0 53m 4.8m
0 53m 4.8m
0 53m 0
0 53m 4.6m
0 53m 4.6m
0 53m 4.6m
0 53m 4.6m
0 53m 0
0 53m 5.0m
0 53m 5.0m
0 53m 5.0m
0 53m 5.0m
0 53m 0
0 53m 4.8m
0 53m 4.8m
0 53m 4.8m
0 53m 4.8m
0 53m 0
0 53m 4.5m
0 53m 4.5m
0 53m 4.5m
0 53m 4.5m
0 53m 0
0 52m 4.5m
0 52m 4.5m
0 52m 4.5m
0 52m 4.5m
0 52m 0
0 52m 5.0m
0 52m 5.0m
0 52m 5.0m
0 52m 5.0m
0 52m 0
0 52m 4.5m
0 52m 4.5m
0 52m 4.5m
0 52m 4.5m
0 52m 0
0 52m 4.6m
0 52m 4.6m
0 52m 4.6m
0 52m 4.6m
0 52m 0
switch:admin> perfshoweemonitor 4/5
There are 7 end-to-end monitor(s) defined on port 5.
KEY SID DID
OWNER_APP OWNER_IP_ADDR TX_COUNT
RX_COUNT CRC_COUNT
------------------------------------------------------------------------------
0 0x21300 0x21dda TELNET N/A 0x00000004d0ba9915
0x0000000067229e65 0x0000000000000000
1 0x21300 0x21ddc TELNET N/A 0x00000004d0baa754
0x0000000067229e65 0x0000000000000000
2 0x21300 0x21de0 TELNET N/A 0x00000004d0bab3a5
0x0000000067229e87 0x0000000000000000
3 0x21300 0x21de1 TELNET N/A 0x00000004d0bac1e4
0x0000000067229e87 0x0000000000000000
4 0x21300 0x21de2 TELNET N/A 0x00000004d0bad086
0x0000000067229e87 0x0000000000000000
5 0x11000 0x21fd6 WEB_TOOLS 192.168.169.40 0x00000004d0bade54
0x0000000067229e87 0x0000000000000000
6 0x11000 0x21fe0 WEB_TOOLS 192.168.169.40 0x00000004d0baed41
0x0000000067229e98 0x0000000000000000
Содержание StorageWorks MSA 2/8 - SAN Switch
Страница 41: ...aliasPurge 41 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also aliasJoin aliasShow fabricShow switchShow ...
Страница 82: ...Fabric OS Commands 82 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also chippropshow ptpropshow ...
Страница 178: ...Fabric OS Commands 178 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also setdbg ...
Страница 222: ...Fabric OS Commands 222 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also ipaddrset ipaddrshow ...
Страница 228: ...Fabric OS Commands 228 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also errNvLogSizeShow errSaveLvlShow errShow ...
Страница 251: ...fabstateshow 251 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fabstateclear fabportshow ...
Страница 258: ...Fabric OS Commands 258 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fanShow fanDisable ...
Страница 263: ...fashow 263 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fazonecreate fastatsshow ...
Страница 301: ...firmwarerestore 301 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also firmwareCommit firmwareDownload ...
Страница 315: ...fwClassInit 315 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwConfigReload fwConfigure fwShow ...
Страница 329: ...fwMailCfg 329 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwconfigure fwclassinit fwshow fwconfigreload ...
Страница 337: ...fwShow 337 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also fwClassInit fwConfigReload fwConfigure ...
Страница 375: ...interfaceShow 375 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portShow switchShow ...
Страница 411: ...logout 411 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also login ...
Страница 446: ...Fabric OS Commands 446 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also version ...
Страница 452: ...Fabric OS Commands 452 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsshow nsallshow nscamshow ...
Страница 455: ...nsaliasshow 455 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsshow nsallshow switchshow ...
Страница 462: ...Fabric OS Commands 462 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also nsAllShow switchShow ...
Страница 493: ...perfCfgClear 493 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgRestore perfCfgSave ...
Страница 495: ...perfCfgRestore 495 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgClear perfCfgSave ...
Страница 497: ...perfCfgSave 497 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfCfgClear perfCfgRestore ...
Страница 518: ...Fabric OS Commands 518 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also perfAddEEMonitor ...
Страница 575: ...portLogDump 575 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portLogClear portLogShow uptime ...
Страница 578: ...Fabric OS Commands 578 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also portLogClear portLogShow uptime ...
Страница 694: ...Fabric OS Commands 694 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also secfabricshow secmodedisable secmodeshow ...
Страница 811: ...switchDisable 811 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also switchEnable switchShow ...
Страница 823: ...switchShow 823 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also switchDisable switchEnable switchName ...
Страница 839: ...syslogdIpRemove 839 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also errShow syslogdIpAdd syslogdIpShow ...
Страница 849: ...timeout 849 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also None ...
Страница 878: ...Fabric OS Commands 878 Fabric OS Version 3 1 x 4 1 x Reference Guide See Also configShow uRouteConfig uRouteShow ...
Страница 910: ...Fabric OS Commands for Licensed Products 910 Fabric OS Version 3 1 x 4 1 x Reference Guide ...