e1200-320 4Gb Fibre Channel Interface Card user and service guide
85
Diagnostics mode
When this option is selected from the System Utilities menu, a confirmation message appears to verify the
selection. If a response of
Y
(yes) is given to the confirmation message, current interface card activities are
interrupted while the unit restarts itself and enters diagnostics mode. The power-up messages appear
followed by the diagnostics menu.
Figure 72
System diagnostics mode
•
Select
1
to perform a loopback test of the Ethernet connection on the interface card unit. For the test to
be performed correctly, an Ethernet loopback connector must be attached to the interface card’s
Ethernet port before selecting this option.
•
Select
2
to perform a loopback test of the Fibre Channel connection on the interface card unit. For the
test to be performed correctly, a Fibre Channel loopback connector must be attached to the interface
card’s Fibre Channel port before selecting this option.
Selecting
X
(exit) from System Diagnostics Mode has a confirmation message to verify the selection. If Y
(yes) is given to the confirmation message, the interface card restarts itself and enters normal operation
mode. The power-up messages appear followed by the main menu.
NOTE:
When exiting System Diagnostics Mode, remove any diagnostics cables before restarting the
unit.
System Diagnostics Mode
X.XX.XX XXXXXX XXXXXXXXXXXXXXXX
07/7/2005 08:56:22
1) Perform Ethernet External Loopback Test
2) Perform Fibre Channel Loopback Test
X) Exit diagnostics mode and reboot
Содержание StorageWorks e1200-320
Страница 26: ...26 Device management ...
Страница 30: ...30 Interface card management ...
Страница 92: ...92 Using the FTP interface ...
Страница 98: ...98 Troubleshooting ...
Страница 102: ...102 Serial and Ethernet pin assignments ...
Страница 108: ...108 Regulatory compliance and safety ...
Страница 122: ...122 Enabling DHCP on the HP e1200 320 4Gb FC Interface Card ...