Installing and Configuring the Director 2/64
56
Director 2/64 Installation Guide
Figure 13: Securing the rear angle brackets
7. Using a torque driver, torque the screws to 22 in/lb.
8. Connect the remaining ends of the PDU power cords to separate PDUs (if
installed), as shown in
Figure 14
; otherwise, connect the two standard AC
power cords.
Note:
Hewlett-Packard recommends installing an optional PDU in the rack.
Hewlett-Packard ships two PDU power cords with the Director 2/64.
WARNING:
Hewlett-Packard power cords are provided for each director
power supply. To prevent personal injury by electric shock, use only the
supplied power cords. Also, verify that the facility power receptacle is the
correct type, supplies the required voltage, and is properly grounded.