Component identification 96
Item LED
Status
Definition
3
Do not remove
Solid white
Do not remove the drive. Removing the drive causes one or more of
the logical drives to fail.
Off
Removing the drive does not cause a logical drive to fail.
4
Drive status
Solid green
The drive is a member of one or more logical drives.
Flashing green
The drive is rebuilding or performing a RAID migration, stripe size
migration, capacity expansion, or logical drive extension, or is
erasing.
Flashing
amber/green
The drive is a member of one or more logical drives and predicts
the drive will fail.
Flashing amber The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
IMPORTANT:
When the SAS-enabled riser board with the Smart Array B320i Controller is
installed in the server, the embedded Smart Array B120i Controller is disabled automatically.
When this condition occurs:
•
Drives connected to the system board operate in AHCI or Legacy mode.
•
In AHCI or Legacy mode, drives cannot be a part of a hardware RAID or a logical drive.
•
The Locate, Drive status, and Do not remove LEDs of the affected drives are disabled.
FBWC module LED definitions
The FBWC module has three single-color LEDs (one amber and two green). The LEDs on the cache module
installed on a storage controller are duplicated on the reverse side of the module to facilitate status viewing.
•
Cache module installed on a storage controller
Содержание ProLiant DL380e Gen8
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 19: ...Illustrated parts catalog 19 ...
Страница 41: ...Removal and replacement procedures 41 o Original release optical drive cage o Redesigned optical drive cage ...
Страница 98: ...Component identification 98 Fan locations ...
Страница 116: ...Cabling 116 o Single rank GPU o Dual rank GPU System board connection options o Primary GPU power cabling ...
Страница 117: ...Cabling 117 o Secondary GPU power cabling ...