Removal and replacement procedures 63
PSU air baffle
To remove the component:
1.
Power down the server (on page
31
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
32
).
o
Remove the server from the rack (on page
34
).
4.
Remove the access panel ("
Access panel
" on page
37
).
5.
If necessary, remove rear drive cables that are secured in the PSU air baffle latches.
6.
Remove the PSU air baffle.
To replace the component, reverse the removal procedure.
Rear drive cage
To remove the component:
1.
Power down the server (on page
31
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
32
).
o
Remove the server from the rack (on page
34
).
4.
Remove the access panel ("
Access panel
" on page
37
).
Содержание ProLiant DL380e Gen8
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 19: ...Illustrated parts catalog 19 ...
Страница 41: ...Removal and replacement procedures 41 o Original release optical drive cage o Redesigned optical drive cage ...
Страница 98: ...Component identification 98 Fan locations ...
Страница 116: ...Cabling 116 o Single rank GPU o Dual rank GPU System board connection options o Primary GPU power cabling ...
Страница 117: ...Cabling 117 o Secondary GPU power cabling ...