Removal and replacement procedures 44
10.
Remove the drive cage assembly.
To replace the component, reverse the removal procedure.
Hot-plug fan blank and module
To provide sufficient airflow to the system if a fan fails, the server supports redundant fans.
Fan population guidelines
Configuration
Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6
One processor,
nonredundant
Blank
Fan
Blank
Fan
Fan
Fan
One processor, redundant
Fan
Fan
Blank
Fan
Fan
Fan
Two processor, nonredundant Fan
Fan
Fan
Fan
Fan
Blank