Removal and replacement procedures 45
Two processor, redundant
Fan
Fan
Fan
Fan
Fan
Fan
•
In a redundant fan mode:
o
If one fan fails, the system continues to operate without redundancy. This condition is indicated by
a flashing amber Health LED.
o
If two fans fail, the system shuts down.
•
The minimum fan requirement to make this server bootable is four fans in bays 2, 4, 5, and 6.
Removing a hot-plug fan blank or module if the server is installed
in a ball-bearing rail system with the cable management arm
CAUTION:
To prevent the potential for thermal damage and system shutdown, ensure that a
functioning server has all feature bays populated with the required component or blank and the
access panel is installed within 60 seconds of being serviced.
To remove the component:
1.
Pull down the quick release levers on each side of the server.
WARNING:
To reduce the risk of personal injury or equipment damage, be sure that the rack is
adequately stabilized before extending a component from the rack.
2.
Extend the server on the rack rails until the server rail-release latches engage.
If the server does not extend from the rack, use a T-25 Torx screwdriver to loosen the screws located
within the lever housing.
3.
Open the latch, slide the access panel to the rear of the chassis, and then remove the access panel.
If the latch is locked, use a T-15 Torx screwdriver to unlock the latch.
4.
Do one of the following:
o
Remove the fan blank.
Содержание ProLiant DL380e Gen8
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 19: ...Illustrated parts catalog 19 ...
Страница 41: ...Removal and replacement procedures 41 o Original release optical drive cage o Redesigned optical drive cage ...
Страница 98: ...Component identification 98 Fan locations ...
Страница 116: ...Cabling 116 o Single rank GPU o Dual rank GPU System board connection options o Primary GPU power cabling ...
Страница 117: ...Cabling 117 o Secondary GPU power cabling ...