Removal and replacement procedures 73
To install the heat sink:
1.
Properly align the heat sink spring-loaded screws to the system board mounting holes.
2.
Tighten the spring-loaded screws clockwise to secure the heat sink connection to the system
board.
Figure 39
Installing the Heat Sink Assembly
NOTE:
When installing two heat sinks, it is recommended to put the heat sinks with the 14-fin side
facing the DIMMs.
CAUTION:
For proper cooling, do not operate the server without the top cover, air baffle, expansion
slot covers, or blanks installed. For additional information, see the user guide. If hot-plug
components are supported, minimize the amount of time the top cover is removed.
To install the air baffle:
1.
Connect all necessary cables.
2.
Gently place the air baffle on the system board.
Figure 40
Installing the Air Baffle