Removal and replacement procedures 110
System fan
The server has four or eight system fans located on the center wall of the chassis. While the server is
equipped with eight system fans, the redundant function is provided.
The figures below identify the system fans by their device number and show their corresponding cable
connections.
Figure 96
Connection of the Four System Fans
Device number
Connector
System fan 1
J63 on the system board
System fan 2
J71 on the system board
System fan 3
J62 on the system board
System fan 4
J68 on the system board
System fans 1 to 3 are for the memory modules and processors, while system fan 4 is for the PCI slots and system
chipsets.