Removal and replacement procedures 102
Power supply unit (PSU)
Located on the rear panel of the server power supply is designed with two types of power supply units.
They are 460 W and 750 W PSU with power factor correction (PFC) function.
Table 21
lists how to
configure the power supply with the different system models.
Table 21
Power Supply Unit Configurations
System model
Power supply unit
4 3.5” HDD model
One or two 460 W power supply unit
8 3.5” HDD model
One or two 460 W power supply unit
8 2.5” HDD model
One or two 460 W power supply unit
12 3.5” HDD model
One or two 750 W power supply unit
25 2.5” HDD model
One or two 750 W power supply unit
Figure 83
Power Supply Unit
WARNING:
Take note of the following reminders to reduce the risk of personal injury from electric
shock hazards and/or damage to the equipment.
•
Installation of power supply units should be referred to individuals who are qualified to service
server systems and are trained to deal with equipment capability of generating hazardous
energy levels.
•
DO
not
open the power supply unit. There are no serviceable parts inside it.
To remove the power supply:
1.
Press the port wine colored tab.
2.
Pull the hot-plug power supply out of the power supply bay
Содержание ProLiant DL180se G6 Server
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 23: ...Illustrated parts catalog 23 ...
Страница 67: ...Removal and replacement procedures 67 Figure 32 Reinstalling the Backplane 3 Install all necessary cables ...
Страница 103: ...Removal and replacement procedures 103 Figure 84 Removing the Power Supply ...
Страница 109: ...Removal and replacement procedures 109 ...