Removal and replacement procedures 59
6.
Install the heatsink:
a.
Position the heatsink on the processor backplate.
b.
Tighten one pair of diagonally opposite screws halfway, and then tighten the other pair of screws.
c.
Finish the installation by completely tightening the screws in the same sequence.
7.
Install the air baffle.
8.
Install the access panel.
9.
Do one of the following:
o
Slide the server into the rack.
o
Install the server into the rack.
10.
Connect each power cord to the server.
11.
Connect each power cord to the power source.
12.
Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
Expansion board
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
To remove the component:
1.
Power down the server (on page
27
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
Содержание ProLiant DL180 Gen9
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 18: ...Illustrated parts catalog 18 ...
Страница 23: ...Illustrated parts catalog 23 ...
Страница 117: ...Cabling 117 Item Description 5 Fan 5 cable GPU power drive cabling FlexibleLOM sideband signal cabling ...
Страница 121: ...Cabling 121 Item Description 3 USB 3 0 connector cable ...