Fan population guidelines
To provide sufficient airflow to the system if a fan fails, the server supports redundant fans.
Configuration
Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5
Non-redundant
Fan
Fan
Blank
Fan
Blank
Redundant*
Fan
Fan
Fan
Fan
Fan
Non-redundant (for
high efficiency
processors
exceeding 105W)
Fan
Fan
Fan
Fan
Blank
* Fan redundancy is not supported for processors exceeding 105W.
•
In the redundant fan mode:
o
If one fan rotor fails, the system continues to operate without redundancy. This condition is indicated
by a flashing amber Health LED.
o
If two fan rotors fail, the system shuts down.
o
The minimum fan requirement to make this server bootable is three fans.
Installing a hot-swap fan module
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
To install the component:
1.
Power down the server (on page
17
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
17
).