Table 2 Minimum requirements, overview category
Minimum requirement
Item
CPU on the server blade: Intel Xeon Processor @ 2.40
Ghz
CPU
37 hard drives, which include the following:
Type and number of drives
•
Slot 2:
35 drives on the HP Smart Array P700m
controller
•
Slot 0:
2 drives on the HP Smart Array P410i
controller
24 GB
Memory
For the HP P4460sb G2 server blade, the Network
Controller is Emulex OneConnect 10Gb NIC:
v2.102.453.0 or later.
NIC
The HP P4000sb server blade has a Broadcom Network
Controller with no minimum requirement.
9.
From the Categories list, select
Storage
.
10.
Verify that the specified item meets the minimum requirements listed in
Table 3 Minimum requirements, storage category
Minimum requirement
Item
Array Controller in Slot 0: HP Smart Array P410i
controller
•
Model: HP P410i
•
Firmware: 3.52 or later
•
Installed Memory: 0 MB
•
BIOS boot device order: 1
Array Controller in Slot 2: HP Smart Array P700m
controller
•
Model: HP P700m
•
Firmware: 7.22 or later
•
Installed Memory: 512 MB
•
Battery1: OK
•
BIOS boot device order: 2
Run server diagnostics
1.
On the HP Insight Diagnostics Test tab, select
Quick Test
and specify the number of loops.
2.
Click
Begin Testing
.
The Survey Tab displays the data from the tests.
Wait for the tests to finish, which may take several minutes.
3.
When the tests have completed, select the
Log
tab and check the failure log to see if the Quick
Test reports any failures.
4.
If the Quick Test reports any errors, fix all errors before continuing.
If you need more information about an error, run a Complete Test on any component that
reported a failure.
If you want to run only specific tests, use the Custom Test option.
For assistance with the Complete or Custom Test options, see the HP SmartStart CD x64 or
contact HP technical support.
5.
Click
Exit Diagnostics
.
6.
Disconnect the HP SmartStart CD x64 from Virtual Media and reboot.
16
Maintaining the HP P4800 G2 solution
Содержание P4800 G2
Страница 4: ...Battery replacement notices 46 Glossary 50 Index 51 4 Contents ...
Страница 40: ...German laser notice Italian laser notice Japanese laser notice 40 Regulatory compliance notices ...
Страница 47: ...French battery notice German battery notice Battery replacement notices 47 ...
Страница 48: ...Italian battery notice Japanese battery notice 48 Regulatory compliance notices ...
Страница 49: ...Spanish battery notice Battery replacement notices 49 ...