4 Removing and replacing the HP P4800 G2 solution
components
This section contains information and procedures specific to replacing the HP P4800 G2 solution
components.
Additional component removal and replacement instructions
For detailed information about the removal and replacement of HP P4800 G2 solution components,
see the resources listed in
. These documents are located on the HP P4800 G2
SAN Solution for BladeSystem documentation CD that accompanies the HP P4800 G2 solution.
Table 4 Component removal and replacement instructions
Resource
Component
HP ProLiant BL460c G7 Server Blade Maintenance and Service Guide
HP P4460sb G2 server blade
HP ProLiant BL460c G6 Server Blade Maintenance and Service Guide
HP P4000sb server blade
HP 3Gb SAS BL Switch Replacement Instructions
HP SAS switch (pass-through modules)
HP Smart Array Controllers for HP ProLiant Servers User Guide
HP Smart Array P700m controller
HP 600 Modular Disk System Maintenance and Service Guide
HP disk enclosures
HP BladeSystem c7000 Enclosure Maintenance and Service Guide
HP c-Class blade enclosure
HP Smart Array Controllers for HP ProLiant Servers User Guide
HP Smart Array P410i controller (BIOS boot
controller)
Identifying hot pluggable and non-hot pluggable components
IMPORTANT:
Hot add and hot removal of the disk enclosures are not supported by HP P4800
G2 SAS BladeSystem SAN Solution.
The following HP P4800 G2 solution components are hot-pluggable; therefore, you do not need
to power down the device before replacing a part:
•
Drives
•
External fans
•
Power supplies
•
Blade disk drives
All other HP P4800 G2 solution components are not hot-pluggable. You must first power down
the device before replacing a part.
CAUTION:
To prevent losing access to data during any maintenance operation on components
of the SAS fabric, including the SAS switches, SAS cables, and I/O modules on the disk enclosure,
first power down the server blades using the procedures to shut down the management group in
the CMC Online Help or HP P4000 SAN Solution User Guide.
Replacing the server blade and server blade components
For more detailed instructions on replacing the server blade or server blade components, see
for resources.
20
Removing and replacing the HP P4800 G2 solution components
Содержание P4800 G2
Страница 4: ...Battery replacement notices 46 Glossary 50 Index 51 4 Contents ...
Страница 40: ...German laser notice Italian laser notice Japanese laser notice 40 Regulatory compliance notices ...
Страница 47: ...French battery notice German battery notice Battery replacement notices 47 ...
Страница 48: ...Italian battery notice Japanese battery notice 48 Regulatory compliance notices ...
Страница 49: ...Spanish battery notice Battery replacement notices 49 ...