Reference
Information
Modem Reference Information
Corporate Evaluator’s Guide
201
Command Function
(Ambit)
&D2
Interpret DTR On-to-OFF transition per &Qn
&Q0 through &Q6: The modem hangs up
&D3
Interpret DTR On-to-OFF transition per &Qn
&Q0, &Q1, &Q4, &Q5, &Q6: Soft reset
&Q2, &Q3: The modem hangs up
&F0
Restore factory configuration 0
&F1
Restore factory configuration 1
&G0
Disable guard tone
&G1
Disable guard tone
&G2
Enable 1800 Hz guard tone
&J0
Set S-Register response only for compatibility
&J1
Set S-Register response only for compatibility
&K0
Disable DTE/DCE flow control
&K3
Enable RTS/CTS DTE/DCE flow control
&K4
Enable XON/XOFF DTE/DCE flow control
&K5
Enable transparent XON/ XOFF low control
&K6
Enable both RTS/CTS and XON/XOFF flow control
&L0
Select dial up line operation
&M0
Select direct asynchronous mode
&M1
Select sync connect with async off-line command mode
&M2
Select sync connect with async off-line command mode and enable DTR dialing of directory zero
&M3
Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch
&P0
Set 10 pps pulse dial with 39%/61% make/break
&P1
Set 10 pps pulse dial with 33%/67% make/break
&P2
Set 20 pps pulse dial with 39%/61% make/break
&P3
Set 20 pps pulse dial with 33%/67% make/break
&Q0
Select direct asynchronous mode
&Q1
Select sync connect with async off-line command mode
&Q2
Select sync connect with async off-line command mode and enable DTR dialing of directory zero
&Q3
Select sync connect with async off-line command mode and enable DTR to act as Talk/Data switch
&Q4
Select Hayes AutoSync mode
&Q5
Modem negotiates an error corrected link
&Q6
Select asynchronous operation in normal mode
&R0
CTS tracks RTS (sync) or CTS is normally ON and will turn OFF only if required by flow control (async)
&R1
CTS is always active (sync) or CTS is normally ON and will turn OFF only if required by flow control (async)
&S0
DSR is always active
&S1
DSR will become active after answer tone has been detected and inactive after the carrier has been lost
&T0
Terminate any test in progress
&T1
Initiate local analog loopback
&T2
Returns ERROR result code
&T3
Initiate local digital loopback
&T4
Allow remote digital loopback (RDL)
&T5
Disallow remote digital loopback request
&T6
Request an RDL without self-test
&T7
Request an RDL with self-test
&T6
Request an RDL without self-test
&T7
Request an RDL with self-test
&T8
Initiate local analog loop with self-test
&V
Display current configuration and stored profiles
Содержание OmniBook 6100
Страница 1: ...HP Omnibook 6100 Corporate Evaluator s Guide ...
Страница 6: ......
Страница 13: ...Corporate Evaluator s Guide 13 Getting Started with Your HP Notebook ...
Страница 29: ...Corporate Evaluator s Guide 29 Basic Operation ...
Страница 49: ...Corporate Evaluator s Guide 49 Batteries and Power Management ...
Страница 57: ...Corporate Evaluator s Guide 57 Modem and Network Connections ...
Страница 72: ......
Страница 73: ...Corporate Evaluator s Guide 73 Add On Devices ...
Страница 96: ......
Страница 97: ...Corporate Evaluator s Guide 97 Using Windows XP ...
Страница 106: ......
Страница 107: ...Corporate Evaluator s Guide 107 Using Windows 2000 ...
Страница 120: ......
Страница 121: ...Corporate Evaluator s Guide 121 Using Windows 98 ...
Страница 134: ......
Страница 135: ...Corporate Evaluator s Guide 135 Using Windows NT 4 0 ...
Страница 150: ......
Страница 151: ...Corporate Evaluator s Guide 151 Troubleshooting and Maintenance ...
Страница 187: ...Corporate Evaluator s Guide 187 HP Support and Service ...
Страница 194: ......
Страница 195: ...Corporate Evaluator s Guide 195 Reference Information ...