Example
Naming Convention
Type of Object
$ZTCP1
$ZTCP
number
Maintenance CIPSAM process
ZTCP1
ZTCP
number
Maintenance provider
$ZTC0
$ZTC
number
IPDATA CIPSAM process
ZTC0
$ZTC
number
IPDATA provider
$ZTNP1
$ZTNP
number
Maintenance Telserv process
$ZTN0
$ZTN
number
Non-maintenance Telserv
process
$ZPRP1
$ZPRP
number
Listener process
$LSN0
$LSN
number
Non-maintenance Listener
process
Possible Values of Disk and Tape LUNs for NS7 Systems
The possible values of disk and tape LUN numbers depend on the type of the resource.
•
For a SAS disk, the LUN number is calculated as
base LUN
+
offset
.
base LUN
is the base LUN number for the SAS enclosure. Its value can be 100, 200, 300,
400, 500, 600, 700, 800, or 900, and should be numbered sequentially for each of the SAS
enclosures attached to the same CLIM.
offset
is the bay (slot) number of the disk in the SAS enclosure.
•
For an ESS disk, the LUN number is calculated as
base LUN
+
offset
.
base LUN
is the base LUN number for the ESS port. Its value can be 1000, 2000, 3000,
4000, 5000, 6000, 7000, 8000, or 9000, and should be numbered sequentially for each of
the ESS ports attached to the same CLIM.
offset
is the LUN number of the ESS LUN.
•
For a physical Fibre Channel tape, the value of LUN number can be 1, 2, 3, 4, 5, 6, 7, 8, or
9, and should be numbered sequentially for each of the physical tapes attached to the same
CLIM.
•
For a VTS tape, the LUN number is calculated as
base LUN
+
offset
.
base LUN
is the base LUN number for the VTS port. Its value can be 5000, 5010, 5020,
5030, 5040, 5050, 5060, 5070, 5080, or 5090, and should be numbered sequentially for
each of the VTS ports attached to the same CLIM.
offset
is the LUN number of the VTS LUN.
60
Managing NS7 System Resources
Содержание Integrity NonStop X NS7
Страница 8: ...Figure 1 Example NS7 System Configurations 42U and 36U 8 HPE Integrity NonStop X NS7 Systems ...
Страница 39: ...Figure 14 Example of Bottom AC Power Feed in a Rack Without UPS AC Power Feeds in the Rack 39 ...
Страница 40: ...Figure 15 Example of Top AC Power Feed in a Rack Without UPS 40 NS7 System Installation Specifications ...
Страница 41: ...Figure 16 Example of Top AC Power Feed in a Rack With Single Phase UPS AC Power Feeds in the Rack 41 ...
Страница 43: ...Figure 18 Example of Top AC Power Feed in a Rack With Three Phase UPS AC Power Feeds in the Rack 43 ...