4 Managing NS7 System Resources
This chapter provides guidelines for managing the system resources.
Planning Kernel Managed Swap (KMS) Space
HPE uses Kernel Managed Swap (KMS) space to manage virtual memory via swap files controlled
by the HPE NonStop operating system. Each CPU has at least one KMS file that provides the
swap space needed by processes.
Proper configuration and management of KMS space is critical to the operation of the system.
After a new system is loaded, HPE recommends initially allocating swap space for each NS7
CPU that equals twice the physical memory of the CPU (for example, 2 x 64GB) minus the
memory configured for DP2 cache. This example shows allocating swap space for a 4 CPU
system with 64GB NonStop X server blades and 128GB server blades.
Total allocation for 4 CPU
system
SWAP File Allocation
Minus DP2 Cache
2x CPU Memory
CPU
448GB
112GB
16GB
128GB
64GB
896GB
224GB
32GB
256GB
128GB
TIP:
If the new system replaces a previous system with a similar number of CPUs and
application processes, you can use the SWAP file usage on that system to help determine the
SWAP file space for the new system.
You use the NonStop Kernel utility program, NSKCOM to monitor, configure, and manage KMS
files. The information you obtain from NSKCOM and MEASURE is then used to adjust the
swap-file configuration.
More information
Measure Reference Manual
Kernel Managed Swap Facility (KMSF) Manual
NonStop X Hardware System Installation Manual
(service providers only)
Default Naming Conventions for NS7 Systems
With a few exceptions, default naming conventions are not necessary for NS7 system resources.
However, default naming conventions have been preconfigured for the following resources to
simplify initial configuration files and automatic generation of these resources.
Example
Naming Convention
Type of Object
NCLIM001
NCLIM
nnn
IP CLuster I/O Module (CLIM)
OCLIM003
OCLIM
nnn
Telco CLIM
SCLIM002
SCLIM
nnn
Storage CLIM
$SAS20
$SAS
number
SAS disk volume
$ESS20
$ESS
number
ESS disk volume
$TAPE01
$TAPE
number
Tape drive
$ZTCP0
$ZTCP
number
Maintenance CIPSAM process
ZTCP0
ZTCP
number
Maintenance provider
Planning Kernel Managed Swap (KMS) Space
59
Содержание Integrity NonStop X NS7
Страница 8: ...Figure 1 Example NS7 System Configurations 42U and 36U 8 HPE Integrity NonStop X NS7 Systems ...
Страница 39: ...Figure 14 Example of Bottom AC Power Feed in a Rack Without UPS AC Power Feeds in the Rack 39 ...
Страница 40: ...Figure 15 Example of Top AC Power Feed in a Rack Without UPS 40 NS7 System Installation Specifications ...
Страница 41: ...Figure 16 Example of Top AC Power Feed in a Rack With Single Phase UPS AC Power Feeds in the Rack 41 ...
Страница 43: ...Figure 18 Example of Top AC Power Feed in a Rack With Three Phase UPS AC Power Feeds in the Rack 43 ...
Страница 62: ...62 HPE Integrity NonStop X NS7 CG X2 System ...