HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 45 of 221
Figure 36 MMI screen to recalibrate press
b. Click
the
Calibrate
button.
c. Click
the
Close
button.
•11. Click the
button on the wizard again to print the Scaling job
Ten copies of the Scaling job are printed and the wizard
Enter Values
step screen is
displayed.
•12. Remove the Scaling job substrate from the press.
Removing the substrate from the press
a. In the Touch Screen Panel (TSP) The System Web Feed screen is
displayed. Press the
Run
button (middle green button) one time and
release it immediately.
b. Press
the
Run
button again and hold the button down until the Scaling
job is completed. Then release the
Run
button. Remove the 10 copies
of the Scaling job from the press.
•1. Examine the Scaling job. The complete Periphery edge lines (see
Figure 37) must be printed on the scale job. If the Periphery edge lines do
not appear fully, perform the Print cleaner procedure then restart the
wizard.