HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 106 of 221
Figure 108 Removing the interlock cable bracket
a. Remove the bracket behind the interlock.
b. Unplug the Upper Nip interlock Molex connector and push the
connector out of the bracket.
Note:
On older presses, the hole in the press wall is too small to push the connector
through. In that case, the interlock cable will be removed with the Output
assembly. The interlock cable must be kept out of the way when the Output
assembly is removed so it won’t be cut by the Output assembly wall.
c. Remove the interlock by unscrewing the screw on top and on bottom
of the bracket.
Note:
Save all screws in a labeled container for reinstallation.