![HP Indigo Press WS4000 Скачать руководство пользователя страница 201](http://html.mh-extra.com/html/hp/indigo-press-ws4000/indigo-press-ws4000_service-manual_163659201.webp)
HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 201 of 221
Figure 243 Clip fits into the sensor
•6. The clip is shaped to fit into the sensor groove and only fits in one
direction. Reinstall the clip into the sensor.
•7. Reinstall the sensor on the sensor strip. The plate on the bottom of the
sensor functions as a nut for the two screws.
•8. The sensor fits snugly into its setting. Ensure that the adjusting screws face
the outside hole on the sensor assembly.
Downloading parameters to the Unidrive using Unisoft
It is not necessary to upload parameters to the Unidrive unless the WHS software is
lower than version 1.03. If the WHS software is lower than version 1.03, use the
Unisoft software to perform the following:
Viewing or changing UniDrive parameter values
UniDrive-keypad.cdr
Up
Right
Down
Left
Modify
Parameter
value
Parameter
name
M
1 2 3.4 5 6
1 2.3 4
Figure 244 UniDrive keypad
The parameter name consists of a 2-digit menu number to the left of the dot and a
2-digit parameter number to the right of the dot. For example, 12.34 is a parameter
name – 12 is the menu number and 34 is the parameter number.
To view the parameter value of a specific parameter, do the following:
•1. Press the left/right arrow buttons to change the menu number of the
parameter name.