HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 37 of 221
•2. In the Main Control Panel, click
Options
and
Press Configuration.
The
Press Configuration window opens.
•3. Go to the Mechanical Devices parameters.
•4. Ensure that the Ink Cabinet is set to
Version 1
.
•5. Ensure that the Inline Densitometer Cooling is
Not installed
.
•6. Go to the Web Handling parameters.
•7. Ensure that the Vacuum Box Type is set to
Version 2
.
•8. At the promt to Restart the press software, click
OK
.
Software testing procedures
Verify ILD firmware version
To verify the ILD firmware version:
•1. Open the press software System Table Editor (SysTab).
•2. Look for the ildPropertiesTopic in the tree.
•3. Look for the ildSoftwareVersion entry in the right pane of the window
For HP Indigo press w3200 look for the ildSoftwareVersion entry in the
right pane of the window of each slave tab.
The value in the Dynamic column should be
X-Rite DTP24
vD303
for the
new ILD firmware. Old firmware version can be
A210
or
9601
.
WHS-software configuration check procedure
To verify whether the new software was installed, perform the following:
Figure 27 System table editor WHS_R_Configuration parameter
•1. In the software menus, go to the System Table Editor.