HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 186 of 221
Note:
The first time you press the
M
button, you must press it for a very short time. Do
not press it for a long, or it will take you out of set parameters mode.
Parameter Value
03 3
05 A1,PR
06 4.8
Enter the code 10
L2
32 ON
Inverter parameters and values
•1. Press the Emergency button before performing this procedure.
•2. Press
the
M
button. The left (parameter) LED shows the previous value
entered, and flickers.
•3. Use the UP and Down arrows to enter the parameter
03
.
•4. Press
the
M
button. The left (parameter) LED displays
03
. The right (value)
LED displays the last value entered and flickers.
•5. Use the UP and Down arrows until the value
3
is displayed in the LED.
•6. Press
the
M
button. The right (value) LED displays
3
. The left (parameter)
LED displays
03
and flickers.
•7. Use the UP and Down arrows to enter the parameter
05
.
•8. Press
the
M
button. The left (parameter) LED displays
05
. The right
(value) LED displays
3
and flickers.
•9. Use the UP and Down arrows until the value
A1,PR
is displayed in the
LED.
•10. Press the
M
button. The right (value) LED shows
A1,PR
. The left
(parameter) LED displays
05
and flickers.
•11. Use the UP and Down arrows to enter the parameter
06
.
•12. Press the
M
button. The left (parameter) LED displays
06
. The right (value)
LED displays
A1,PR
and flickers.
•13. Use the UP and Down arrows until the value
4.8
is displayed in the LED.
•14. Press the
M
button. The right (value) LED shows
4.8
. The left (parameter)
LED displays
06
and flickers.
•15. Use the UP and Down arrows to enter the code
10
.
•16. Press the
M
button. The left (parameter) LED displays
10
. The right (value)
LED displays
4.8
and flickers.
•17. Use the UP and Down arrows until the value
L2
is displayed in the LED.
•18. Press the
M
button. The right (value) LED shows
L2
. The left (parameter)
LED displays
10
and flickers.