124
Fabric OS Administrator’s Guide
53-1002745-02
Frame order delivery
4
Using Frame Viewer to understand why frames are dropped
When a frame is unable to reach its destination due to timeout, it is discarded. You can use
Frame Viewer to find out which flows contained the dropped frames, which in turn can help you
determine which applications might be impacted. Frame Viewer allows you to see the exact time
(within one second) that the frames were dropped.
You can view and filter up to 20 discarded frames per chip per second for 1200 seconds using a
number of fields with the frameLog command.
Use the following procedure to view frames.
1. Connect to the switch and log in using an account with admin permissions.
2. Type frameLog
--
show.
Example output of
framelog --show
EDCX16_114064:root>
framelog --show
==================================================================================================
Fri Jul 13 23:47:08 UTC 2012
==================================================================================================
Log
TX
RX
timestamp
port
port
SID
DID
SFID
DFID
Type
Count
===============================================================================================
Jul 13 23:47:07
11/45
11/45
0xfffffd
0x40e580
0
0
timeout
2
Jul 13 23:47:07
11/45
11/45
0xfffffc
0x40e580
0
0
timeout
5
Jul 13 23:47:07
11/45
11/45
0xfffffc
0x40e580
0
0
timeout
3
Jul 13 23:47:07
11/45
11/45
0xfffc40
0x40e580
0
0
timeout
2
Jul 13 23:47:07
11/45
11/45
0xfffc40
0x40e580
0
0
timeout
1
Notes
The output of
--
show displays the type of each discard.
Syntax
framelog --show
[-type <discard_type>]
[-txport <[slot/]port>] [-rxport
<[slot/]port>] [-sid <source_PID>] [-did <destination_PID>] [-sfid <source_FID>]
[-dfid <destination_FID>] [-mode summary | dump] [-n <num_items>]
Constraints
The following constraint applies to the frameLog
--
show command:
•
The -type option requires an argument; currently only timeout is supported, this specifies that
only timeout discards be shown
Filtering Results by Back-End Port in Frame Viewer
The Frame Viewer --show command supports specifying that the TX port or RX port of displayed
frames should be a back-end port. To filter by TX port or RX port, you issue a command like:
framelog
--show -txport [<slot>/]<port>
or
framelog
--show -rxport [<slot>/]<port>
or
framelog
--show -txport [<slot>/]<port> -rxport [<slot>/]<port>
Содержание Fabric OS 7.1.0
Страница 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Страница 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 116: ...116 Fabric OS Administrator s Guide 53 1002745 02 Inter switch links 4 FIGURE 7 Virtual channels on a QoS enabled ISL ...
Страница 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Страница 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Страница 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Страница 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Страница 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Страница 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Страница 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Страница 432: ...432 Fabric OS Administrator s Guide 53 1002745 02 Access Gateway N_Port failover with FA PWWN 16 ...
Страница 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Страница 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...