Fabric OS Administrator’s Guide
199
53-1002745-02
FCS policies
7
Example of aborting unsaved changes
switch:admin>
secpolicyabort
Unsaved data has been aborted.
All changes since the last time the secPolicySave or secPolicyActivate commands were entered are
aborted.
FCS policies
Fabric configuration server (FCS) policy in base Fabric OS may be performed on a local switch basis
and may be performed on any switch in the fabric.
The FCS policy is not present by default, but must be created. When the FCS policy is created, the
WWN of the local switch is automatically included in the FCS list. Additional switches can be
included in the FCS list. The first switch in the list becomes the Primary FCS switch.
Switches in the fabric are designated as either a Primary FCS, backup FCS, or non-FCS switch. Only
the Primary FCS switch is allowed to modify and distribute the database within the fabric.
Automatic distribution is supported and you can either configure the switches in your fabric to
accept the FCS policy or manually distribute the FCS policy. Changes made to the FCS policy are
saved to permanent memory only after the changes have been saved or activated; they can be
aborted later if you have set your fabric to distribute the changes manually.
FCS policy restrictions
The backup FCS switches normally cannot modify the policy. However, if the Primary FCS switch in
the policy list is not reachable, then a backup FCS switch is allowed to modify the policy.
Once an FCS policy is configured and distributed across the fabric, only the Primary FCS switch can
perform certain operations. Operations that affect fabric-wide configuration are allowed only from
the Primary FCS switch. Backup and non-FCS switches cannot perform security, zoning and AD
operations that affect the fabric configuration. The following error message is returned if a backup
or non-FCS switch tries to perform these operations:
Can only execute this command on the Primary FCS switch.
Operations that do not affect the fabric configuration, such as
show
or local switch commands, are
allowed on backup and non-FCS switches.
FCS enforcement applies only for user-initiated fabric-wide operations. Internal fabric data
propagation because of a fabric merge is not blocked. Consequently, a new switch that joins the
FCS-enabled fabric could still propagate the AD and zone database.
TABLE 29
FCS policy states
Policy state
Characteristics
No active policy
Any switch can perform fabric-wide configuration changes.
Active policy with one entry
A Primary FCS switch is designated (local switch), but there are no backup
FCS switches. If the Primary FCS switch becomes unavailable for any reason,
the fabric is left without an FCS switch.
Active policy with multiple entries
A Primary FCS switch and one or more backup FCS switches are designated. If
the Primary FCS switch becomes unavailable, the next switch in the list
becomes the Primary FCS switch.
Содержание Fabric OS 7.1.0
Страница 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Страница 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 116: ...116 Fabric OS Administrator s Guide 53 1002745 02 Inter switch links 4 FIGURE 7 Virtual channels on a QoS enabled ISL ...
Страница 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Страница 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Страница 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Страница 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Страница 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Страница 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Страница 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Страница 432: ...432 Fabric OS Administrator s Guide 53 1002745 02 Access Gateway N_Port failover with FA PWWN 16 ...
Страница 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Страница 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Страница 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Страница 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Страница 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...