290
Fabric OS Administrator’s Guide
53-1002745-02
Enabling Virtual Fabrics mode
10
Enabling Virtual Fabrics mode
A fabric is said to be in
Virtual Fabrics mode
(VF mode) when the Virtual Fabrics feature is enabled.
Before you can use the Virtual Fabrics features, such as logical switch and logical fabric, you must
enable VF mode.
VF mode is enabled by default.
NOTE
When you enable VF mode, the control processors (CPs) are rebooted and all EX_Ports are disabled
after the reboot.
Use the following procedure to enable Virtual Fabrics mode:
1. Connect to the physical chassis and log in using an account with the chassis-role permission.
2. Use the fosConfig command to check whether VF mode is enabled:
fosconfig --show
3. Delete all Admin Domains, as described in
“Deleting all user-defined Admin Domains
non-disruptively”
on page 450.
4. Use the fosConfig command to enable VF mode:
fosconfig --enable vf
5. Enter y at the prompt.
Example
The following example checks whether VF mode is enabled or disabled and then enables it.
switch:admin>
fosconfig --show
FC Routing service:
disabled
iSCSI service:
Service not supported on this Platform
iSNS client service:
Service not supported on this Platform
Virtual Fabric:
disabled
Ethernet Switch Service:
Service not supported on this Platform
switch:admin>
fosconfig --enable vf
WARNING:
This is a disruptive operation that requires a reboot to take
effect.
All EX ports will be disabled upon reboot.
Would you like to continue [Y/N]
y
VF has been enabled. Your system is being rebooted.
Disabling Virtual Fabrics mode
When you disable VF mode, the following occurs:
•
The CPs are rebooted.
•
If F_Port trunking is enabled on ports in the default switch, the F_Port trunking information is
deleted.
ATTENTION
If you want to use Admin Domains in a fabric, you must first disable VF mode.
Содержание Fabric OS 7.1.0
Страница 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Страница 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 116: ...116 Fabric OS Administrator s Guide 53 1002745 02 Inter switch links 4 FIGURE 7 Virtual channels on a QoS enabled ISL ...
Страница 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Страница 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Страница 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Страница 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Страница 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Страница 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Страница 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Страница 432: ...432 Fabric OS Administrator s Guide 53 1002745 02 Access Gateway N_Port failover with FA PWWN 16 ...
Страница 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Страница 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Страница 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Страница 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Страница 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...