44
Fabric OS Administrator’s Guide
53-1002745-02
Management server
1
Management server — The management server provides a single point for managing the fabric.
This is the only service that users can configure. See
“Management server”
below for more details
Alias server — The alias server keeps a group of nodes registered as one name to handle multicast
groups.
Broadcast server — The broadcast server is optional. When frames are transmitted to this address,
they are broadcast to all operational N_ and NL_Ports.
When registration and query frames are sent to a well-known address, a different protocol service,
Fibre Channel Common Transport (FC-CT), is used. This protocol provides a simple, consistent
format and behavior when a service provider is accessed for registration and query purposes.
Management server
The Brocade Fabric OS management server (MS) allows a SAN management application to retrieve
information and administer interconnected switches, servers, and storage devices. The
management server assists in the autodiscovery of switch-based fabrics and their associated
topologies.
A client of the management server can find basic information about the switches in the fabric and
use this information to construct topology relationships. The management server also allows you to
obtain certain switch attributes and, in some cases, modify them. For example, logical names
identifying switches can be registered with the management server.
The management server provides several advantages for managing a Fibre Channel fabric:
•
It is accessed by an external Fibre Channel node at the well-known address
FFFFFAh
, so an
application can access information about the entire fabric management with minimal
knowledge of the existing configuration.
•
It is replicated on every Brocade switch within a fabric.
•
It provides an unzoned view of the overall fabric configuration. This fabric topology view
exposes the internal configuration of a fabric for management purposes; it contains
interconnect information about switches and devices connected to the fabric. Under normal
circumstances, a device (typically an FCP initiator) queries the name server for storage devices
within its member zones. Because this limited view is not always sufficient, the management
server provides the application with a list of the entire name server database.
Platform services
By default, all management services except platform services are enabled; the MS platform service
and topology discovery are disabled.
You can activate and deactivate the platform services throughout the fabric. Activating the platform
services attempts to activate the MS platform service for each switch in the fabric. The change
takes effect immediately and is committed to the configuration database of each affected switch.
MS activation is persistent across power cycles and reboots.
NOTE
The commands msplMgmtActivate and msplMgmtDeactivate are allowed only in AD0 and AD255.
Содержание Fabric OS 7.1.0
Страница 1: ...53 1002745 02 25 March 2013 Fabric OS Administrator s Guide Supporting Fabric OS 7 1 0 ...
Страница 24: ...24 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 28: ...28 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 32: ...32 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 42: ...42 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 116: ...116 Fabric OS Administrator s Guide 53 1002745 02 Inter switch links 4 FIGURE 7 Virtual channels on a QoS enabled ISL ...
Страница 132: ...132 Fabric OS Administrator s Guide 53 1002745 02 Frame Redirection 4 ...
Страница 194: ...194 Fabric OS Administrator s Guide 53 1002745 02 Ports and applications used by switches 6 ...
Страница 254: ...254 Fabric OS Administrator s Guide 53 1002745 02 Brocade configuration form 8 ...
Страница 274: ...274 Fabric OS Administrator s Guide 53 1002745 02 Validating a firmware download 9 ...
Страница 302: ...302 Fabric OS Administrator s Guide 53 1002745 02 Creating a logical fabric using XISLs 10 ...
Страница 344: ...344 Fabric OS Administrator s Guide 53 1002745 02 Concurrent zone transactions 11 ...
Страница 374: ...374 Fabric OS Administrator s Guide 53 1002745 02 Setting up TI over FCR sample procedure 12 ...
Страница 432: ...432 Fabric OS Administrator s Guide 53 1002745 02 Access Gateway N_Port failover with FA PWWN 16 ...
Страница 462: ...462 Fabric OS Administrator s Guide 53 1002745 02 ...
Страница 490: ...490 Fabric OS Administrator s Guide 53 1002745 02 Ports on Demand 18 ...
Страница 498: ...498 Fabric OS Administrator s Guide 53 1002745 02 Supported topologies for ICL connections 19 ...
Страница 626: ...626 Fabric OS Administrator s Guide 53 1002745 02 Preparing a switch for FIPS B ...
Страница 630: ...630 Fabric OS Administrator s Guide 53 1002745 02 Hexadecimal Conversion C ...
Страница 666: ...666 Fabric OS Administrator s Guide 53 1002745 02 ...