Chapter 6
Troubleshooting
39
To clear the configuration:
1. Turn off the power switch on the NetServer and remove the cover and the
cooling duct.
2. Move the system board switch 6 to the closed position to clear the
configuration.
3. Turn on the power switch on the NetServer. A message displays indicating
that the configuration has been cleared.
4. Turn off the power switch on the NetServer.
5. Return the system board switch 6 to the open position.
6. Replace the cooling duct and the cover.
7. Turn on the power switch on the NetServer. The message
Incorrect PC Configuration
Option ROM error
is displayed.
8. Press [F2] to run the Setup program when
<F2=Setup>
appears.
9. Make any configuration changes that are required.
10. Choose the Exit option and save the changes to save the configuration and
exit the Setup program.
Power-On System Hardware Test Error Messages
There are two kinds of error messages that may prevent the NetServer from
booting. These are:
•
Messages in reverse video (black text on white background). Press the
Return key to see a definition of the message and what action to take to
remedy the problem.
•
Power-on system hardware test errors. These display in normal video
(white text on black background).
The following table describes these errors and the corrective action you may take
to remedy the problem:
Message