![HP Compaq Presario,Presario 1910 Скачать руководство пользователя страница 91](http://html.mh-extra.com/html/hp/compaq-presario-presario-1910/compaq-presario-presario-1910_user-manual_161851091.webp)
78
Item Description
MDI
Set the Medium Dependent Interface (MDI) mode of the port.
You can use two types of Ethernet cables to connect Ethernet devices: crossover cable and
straight-through cable. To accommodate these two types of cables, an Ethernet port can
operate in one of the following MDI modes: across, normal, and auto.
An Ethernet port is composed of eight pins. By default, each pin has its particular role. For
example, pin 1 and pin 2 are used for transmitting signals, and pin 3 and pin 6 are used
for receiving signals. You can change the pin roles by setting the MDI mode.
•
For an Ethernet port in across mode, pin 1 and pin 2 are used for transmitting signals,
and pin 3 and pin 6 are used for receiving signals. The pin roles are not changed.
•
For an Ethernet port in auto mode, the pin roles are decided through autonegotiation.
•
For an Ethernet port in normal mode, the pin roles are changed. Pin 1 and pin 2 are
used for receiving signals, and pin 3 and pin 6 are used for transmitting signals.
To enable correct communication, you must connect the local transmit pins to the remote
receive pins.
When you configure the MID mode, follow these guidelines:
•
Typically, use the
auto
mode. The other two modes are used only when the device
cannot determine the cable type.
•
When straight-through cables are used, the local MDI mode must be different from the
remote MDI mode.
•
When crossover cables are used, the local MDI mode must be the same as the remote
MDI mode, or the MDI mode of at least one end must be set to
auto
.
Flow Control
Enable or disable flow control on the port.
With flow control enabled at both sides, when traffic congestion occurs on the ingress
port, the ingress port sends a Pause frame notifying the egress port to temporarily suspend
the sending of packets. The egress port is expected to stop sending any new packet when
it receives the Pause frame. In this way, flow control helps to avoid dropping of packets.
Flow control works only after it is enabled on both the ingress and egress ports.
Power Save
Enable or disable auto power down on the port.
With auto power down enabled, when an Ethernet port does not receive any packet for
a certain period of time, it automatically enters the power save mode and resumes its
normal state upon the arrival of a packet.
Support for this configuration item varies with device models.
Max MAC Count
Set the MAC learning limit on the port:
•
User Defined
—Select this option to set the limit manually.
•
No Limited
—Select this option to set no limit.
Содержание Compaq Presario,Presario 1910
Страница 35: ...22 Figure 16 Sort display based on MAC address in the ascending order ...
Страница 54: ...41 Figure 27 Configuration finishes ...
Страница 70: ...57 Figure 42 Configuring idle timeout period 3 Set the idle timeout period for logged in users 4 Click Apply ...
Страница 98: ...85 Figure 67 Displaying the rate settings of ports ...
Страница 114: ...101 Figure 82 Port traffic statistics NOTE When the bandwidth utilization is lower than 1 1 is displayed ...
Страница 158: ...145 Field Description OutErrors Number of invalid packets sent through the interface ...
Страница 202: ...189 Figure 177 Creating a static MAC address entry ...
Страница 230: ...217 Figure 193 Configuring MSTP globally on Switch D ...
Страница 359: ...346 5 View the operation result in the Summary area Figure 316 IPv6 traceroute operation result ...