Chapter 1
System Components
15
Table 1-3 describes the LEDs on the drive module.
Table 1-3
Drive Module LED Combinations (Front)
Online/Activity
(green)
Fault/UID
(amber/blue)
Description
On
Off
The drive is online, but it is not currently active.
Blinking
irregularly
Off
The drive is active and operating normally.
Off
Amber, blinking
regularly (1 Hz)
Offline; the drive is not being accessed. A predictive
failure alert may have been received for this device.
Further investigation is required.
On
Amber, blinking
regularly (1 Hz)
Online; no activity. A predictive failure alert may have
been received for this device. Further investigation is
required.
Blinking
irregularly
Amber, blinking
regularly (1 Hz)
The drive is active, but a predictive failure alert may
have been received for this drive. Further investigation
is required.
Off
Amber, solid
Offline; no activity. A critical fault condition has been
identified for this drive.
Off
Blue; solid
Offline. The drive has been selected by a management
application.
On or blinking
Blue; solid
The drive is operating normally, and it has been selected
by a management application.
Blinking regularly
(1 Hz)
Off
Do not remove the drive. Removing a drive may
terminate the current operation and cause data loss.
The drive is rebuilding.
Off
Off
Either there is no power, the drive is offline, or the drive
is not configured.
Содержание AA988A - Modular Smart Array Storage Controller SCSI
Страница 1: ...HP StorageWorks 2012sa Modular Smart Array user guide Part number 488320 002 Second edition July 2008 ...
Страница 24: ...24 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Страница 52: ...52 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Страница 70: ...70 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Страница 83: ...Appendix B Regulatory Compliance and Safety 83 Japanese Notice Korean Notices ...
Страница 102: ...102 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...