background image

User's
Manual

All Rights Reserved, Copyright © 
2014 Yokogawa Test & Measurement Corporation
Printed in Japan

Thank you for purchasing the AC adapter.
This product is designed to be used by a person with specialized knowledge.
This User's Manual describes the specifications and handling precautions of the AC adapter.
Before using the AC adapter, thoroughly read this manual to get a clear understanding on proper use.
For detailed handling procedures, refer to the instrument (main unit) User's Manual.
This manual is an essential part of the product; keep it a safe place for future reference.

WARNING

 

• To prevent the possibility electrical shock or fire, be sure to use the AC adapter and 

 

the power cord supplied by YOKOGAWA.

• This product is intended for use in combination with Yokogawa products that refer to it only.
• Check that the power source voltage matches the supply voltage rating of the AC adapter, 

 

and then connect to the outlet.

• Check that the power switch of the instrument is turned OFF and then connect the AC adapter.
• If the instrument is not used for a prolonged period, disconnect the AC adapter from the outlet.
• Do not place anything on the AC adapter or power cord, and prevent heat sources from coming 

 

into contact with them.

• When unplugging the power cord from the outlet, be sure to hold the plug and never pull 

 

the actual cord.

• When cleaning the AC adapter, disconnect the AC adapter from the outlet and gentry wipe 

 

the external surfaces with a soft clean cloth. Do not use chemical such as benzine or thinner.

• Do not throw (dispose of ) the AC adapter in fire or apply heat to it.
• Do not use it, where the code is bundled (bent).
• If the power cord is damaged, contact your dealer.

Model

Suffix Code

Specifications

94016

-F

-S

Power cord: 

VDE standard

BS standard

Make sure that the attached power cord meets the designated standards of the country and  

area that you are using it in.

■ Specifications (Power Supply Rating of the AC Adapter)

Rated supply voltage: 

220 to 240 VAC

Rated supply frequency: 

50/60 Hz

No load Current: 

45 mA

Output voltage rating of AC adapter: 

8.5 VDC, 150 mADC

Operating temperature: 

-10 to 40°C

Safety standards: 

EN 60950-1

 

Pollution degree 2, Indoor use, 

 

 

Altitude 2000 m or less

EMC standards: 

EN 55032 Class B, EN 55024

 

EN 61000-3-2, EN 61000-3-3

94016

AC Adapter

IM 94016-EN

5th Edition: Oct. 2017 (YMI)