Chapter 4
Configuring a System for the First Time
45
As shown in the following example, network parameters, including the IP address,
gateway address, and subnet mask are displayed for each controller.
8. In the host computer's command window, type the following command to verify
Ethernet connectivity, first for controller A and then for controller B:
If you cannot access your system three minutes
after changing the IP address
,
your network might require you to restart the management controller using the CLI.
When you restart a management controller, communication with it is temporarily
lost until it successfully restarts.
Type the following command to restart the management controller on both
controllers:
9. After you have verified Ethernet connectivity, disconnect the serial cable and exit
the emulator.
Network Parameters Controller A
--------------------------------
IP Address
: 192.168.0.10
Gateway
: 192.168.0.1
Subnet Mask
: 255.255.0.0
MAC Address
: 00:00:FF:D5:01:4D
Addressing Mode
: Manual
Network Parameters Controller B
--------------------------------
IP Address
: 192.168.0.11
Gateway
: 192.168.0.1
Subnet Mask
: 255.255.0.0
MAC Address
: 00:C0:FF:D5:01:15
Addressing Mode
: Manual
ping
IP-address
restart mc both
Содержание AA988A - Modular Smart Array Storage Controller SCSI
Страница 1: ...HP StorageWorks 2012sa Modular Smart Array user guide Part number 488320 002 Second edition July 2008 ...
Страница 24: ...24 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Страница 52: ...52 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Страница 70: ...70 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...
Страница 83: ...Appendix B Regulatory Compliance and Safety 83 Japanese Notice Korean Notices ...
Страница 102: ...102 HP StorageWorks 2012sa Modular Smart Array user guide May 2008 ...