249
Chapter 6, Call Processing Subsystem
Using the ANALOG MEAS Screen
To Make an FM Hum and Noise Measurement
1. If not already done, condition the Test Set.
See "Conditioning the Test Set for Call
for further information.
2. If not already done, configure the Test Set.
See "Configure the Test Set" on page 142
for further information.
3. Connect the mobile station to the Test Set as shown in
Mobile Station to the Test Set," on page 119
.
NOTE:
The mobile station’s speaker output must be connected to the Test Set’s AUDIO IN and the
mobile station’s microphone input must be connected to the Test Set’s AUDIO OUT in order
to use the ANALOG MEAS screen.
4. Turn on the mobile station.
Ensure that the Test Set is in the connected state.
See "Page a Mobile Station" on page
for information on how to bring a mobile station up on a voice channel.
5. If the ANALOG MEAS screen is not displayed, select the
ANLG MEAS
field from the
To Screen
menu. The ANALOG MEAS screen will be displayed.
NOTE:
It is recommended that the mobile station’s microphone be muted, if possible, when making
measurements on the mobile stations RF carrier. If the microphone is not muted it is possible
for extraneous noise to be picked up by the microphone and adversely affect the
measurements.
6. The following example illustrates how to make a FM Hum and Noise measurement:
a. Select the
Amplitude
field and set it to
−
47 dBm.
b. Select the
AFGen1 Freq
field and set it to 1 kHz.
c. Select the upper
AFGen1 To
field and set it to
Audio Out
.
d. Select the
AF Anl In
field and select
FM Demod
.
e. Select the
Filter 1
field and select
C MESSAGE
.
f.
Select the
Filter 2
field and select
>99kHz LP
.
g. Position the cursor on the
De-Emphasis
field and select
750 us
.
h. Select the
Detector
field and select
PK+
.
i.
Select the measurement field and select
AF Freq
.
j.
Select the lower
AFGen1 To
field and adjust the signal level until the
FM Devi-
ation
field on the upper portion of the CRT reads 8 kHz.
k. Select the
Detector
field and select
RMS
.
l.
Select the
FM Deviation
field.
m. Press the blue SHIFT key, the INCR -10 key, then the ENTER key. This sets a zero
reference point.
n. Select the lower
AFGen1 To
field and press the ON/OFF key. This turns off the
modulating signal to the mobile station transmitter.
o. The FM Hum and Noise figure is displayed in the
FM Deviation
field.
Содержание 8920A
Страница 14: ...Contents 14 2 Configuring Your Test Set General Operating Information 50 ...
Страница 17: ...Contents 17 5 AF Analyzer Screen Block Diagram 100 ...
Страница 19: ...Contents 19 7 Configure Screen Field Descriptions 254 ...
Страница 21: ...Contents 21 9 Duplex Test Screen Block Diagram 340 Field Descriptions 341 ...
Страница 23: ...Contents 23 11 Help Screen Field Descriptions 436 ...
Страница 24: ...Contents 24 12 I O Configure Screen Field Descriptions 438 ...
Страница 25: ...Contents 25 13 Message Screen Field Descriptions 444 ...
Страница 26: ...Contents 26 14 Oscilloscope Screen Field Descriptions 446 Using the Oscilloscope 452 ...
Страница 27: ...Contents 27 15 Print Configure Screen Field Descriptions 454 ...
Страница 29: ...Contents 29 17 RF Analyzer Screen Block Diagram 472 Field Descriptions 473 ...
Страница 30: ...Contents 30 18 RF Generator Screen Block Diagram 484 Field Descriptions 485 ...
Страница 31: ...Contents 31 19 RX Test Screen Block Diagram 494 Field Descriptions 495 ...
Страница 32: ...Contents 32 20 Service Screen Field Descriptions 502 ...
Страница 33: ...Contents 33 21 Spectrum Analyzer Screen Field Descriptions 506 Using the Spectrum Analyzer 518 ...
Страница 35: ...Contents 35 23 TX Test Screen Block Diagram 550 Field Descriptions 551 ...
Страница 38: ...Contents 38 Index 619 ...
Страница 39: ...39 1 Get Started ...
Страница 52: ...52 S HP892XX USRGUIDE manual configts fb Chapter 2 Configuring Your Test Set General Operating Information ...
Страница 98: ...98 S HP892XX USRGUIDE manual acpscrn fb Chapter 4 Adjacent Channel Power Screen Field Descriptions ...
Страница 99: ...99 5 AF Analyzer Screen ...
Страница 113: ...113 6 Call Processing Subsystem ...
Страница 129: ...129 Chapter 6 Call Processing Subsystem The CALL CONTROL Screen Figure 20 AMPS CALL CONTROL Screen with Meas Selected ...
Страница 252: ...252 S HP892XX USRGUIDE manual callscrn fb Chapter 6 Call Processing Subsystem CALL CONFIGURE Screen ...
Страница 268: ...268 S HP892XX USRGUIDE manual confscrn fb Chapter 7 Configure Screen Field Descriptions ...
Страница 269: ...269 8 Signaling Decoder Screen ...
Страница 338: ...338 S HP892XX USRGUIDE manual decoscrn fb Chapter 8 Signaling Decoder Screen Tone Sequence Decoder ...
Страница 339: ...339 9 Duplex Test Screen ...
Страница 353: ...353 10 Signaling Encoder AF Generator 2 ...
Страница 435: ...435 11 Help Screen ...
Страница 437: ...437 12 I O Configure Screen ...
Страница 443: ...443 13 Message Screen ...
Страница 445: ...445 14 Oscilloscope Screen ...
Страница 456: ...456 S HP892XX USRGUIDE manual prinscrn fb Chapter 15 Print Configure Screen Field Descriptions ...
Страница 471: ...471 17 RF Analyzer Screen ...
Страница 482: ...482 S HP892XX USRGUIDE manual rfanscrn fb Chapter 17 RF Analyzer Screen Field Descriptions ...
Страница 483: ...483 18 RF Generator Screen ...
Страница 492: ...492 S HP892XX USRGUIDE manual rfgscrn fb Chapter 18 RF Generator Screen Field Descriptions ...
Страница 493: ...493 19 RX Test Screen ...
Страница 504: ...504 S HP892XX USRGUIDE manual servscrn fb Chapter 20 Service Screen Field Descriptions ...
Страница 519: ...519 22 Tests Screen ...
Страница 548: ...548 S HP892XX USRGUIDE manual testscrn fb Chapter 22 Tests Screen ROM Programs ...
Страница 549: ...549 23 TX Test Screen ...
Страница 551: ...551 Chapter 23 TX Test Screen Field Descriptions Field Descriptions Figure 145 The TX Test Screen txscrn wmf ...
Страница 561: ...561 24 Connector Key and Knob Descriptions ...
Страница 585: ...585 25 Modifications Accessories Manuals Support ...
Страница 605: ...605 Error Messages ...
Страница 618: ...618 S HP892XX USRGUIDE manual errormsg fb Error Messages ...