153
Chapter 6, Call Processing Subsystem
Using the CALL CONTROL Screen to test AMPS Authentication
Configure the Test Set
1. Select
CALL CNTL
from the
To Screen
menu. The CALL CONTROL screen will
be displayed.
2. Verify that the Test Set configuration information is appropriate for the mobile station
to be tested. Check the following fields:
a.
System Type
- Select AMPS. At this time, only AMPS is supported for authen-
tication.
NOTE:
If the
System Type
field was modified in step 2a- the control channel will become active
since modifying this field automatically activates the control channel. Refer to the
field description, on page 136
b.
Cntl Channel
- Set the control channel number to be used by the Test Set.
NOTE:
If the
Cntl Channel
field was modified in step 2b the control channel will become active
since modifying this field automatically activates the control channel. Refer to the
field description, on page 126
c.
Amplitude
- Set the output power of the Test Sets’s transmitter (that is, the output
power of the Test Set’s RF Generator).
d.
SID
- Enter the system identification number of the Test Set as a decimal number.
e.
Chan:
(right-hand field) - Enter the voice channel number which will be assigned
to the mobile station by the Test Set as either an initial voice channel assignment or
as a handoff voice channel assignment.
f.
Pwr Lvl:
(right-hand field) - Enter the Voice Mobile Attenuation Code (VMAC).
The VMAC determines the mobile station power level to be used on the voice chan-
nel (See
field description, on page 125
for more information about the
voice channel).
g.
SAT:
(right-hand field) - Enter the SAT frequency to be used on the designated
voice-channel (See
field description, on page 125
for more information
about the voice channel).
3. Select
CALL CNFG
under the
To Screen
menu. The CALL CONFIGURATION
screen will be displayed.
4. Verify that the Test Set’s configuration information is appropriate for the mobile station
to be tested. Check the following field:
a.
CMAX
- Set the number of access channels in the system. This will determine how
many channels must be scanned by the mobile station when trying to access the Test
Set. The value of this field will affect the time required for the mobile station to con-
nect with the Test Set.
Содержание 8920A
Страница 14: ...Contents 14 2 Configuring Your Test Set General Operating Information 50 ...
Страница 17: ...Contents 17 5 AF Analyzer Screen Block Diagram 100 ...
Страница 19: ...Contents 19 7 Configure Screen Field Descriptions 254 ...
Страница 21: ...Contents 21 9 Duplex Test Screen Block Diagram 340 Field Descriptions 341 ...
Страница 23: ...Contents 23 11 Help Screen Field Descriptions 436 ...
Страница 24: ...Contents 24 12 I O Configure Screen Field Descriptions 438 ...
Страница 25: ...Contents 25 13 Message Screen Field Descriptions 444 ...
Страница 26: ...Contents 26 14 Oscilloscope Screen Field Descriptions 446 Using the Oscilloscope 452 ...
Страница 27: ...Contents 27 15 Print Configure Screen Field Descriptions 454 ...
Страница 29: ...Contents 29 17 RF Analyzer Screen Block Diagram 472 Field Descriptions 473 ...
Страница 30: ...Contents 30 18 RF Generator Screen Block Diagram 484 Field Descriptions 485 ...
Страница 31: ...Contents 31 19 RX Test Screen Block Diagram 494 Field Descriptions 495 ...
Страница 32: ...Contents 32 20 Service Screen Field Descriptions 502 ...
Страница 33: ...Contents 33 21 Spectrum Analyzer Screen Field Descriptions 506 Using the Spectrum Analyzer 518 ...
Страница 35: ...Contents 35 23 TX Test Screen Block Diagram 550 Field Descriptions 551 ...
Страница 38: ...Contents 38 Index 619 ...
Страница 39: ...39 1 Get Started ...
Страница 52: ...52 S HP892XX USRGUIDE manual configts fb Chapter 2 Configuring Your Test Set General Operating Information ...
Страница 98: ...98 S HP892XX USRGUIDE manual acpscrn fb Chapter 4 Adjacent Channel Power Screen Field Descriptions ...
Страница 99: ...99 5 AF Analyzer Screen ...
Страница 113: ...113 6 Call Processing Subsystem ...
Страница 129: ...129 Chapter 6 Call Processing Subsystem The CALL CONTROL Screen Figure 20 AMPS CALL CONTROL Screen with Meas Selected ...
Страница 252: ...252 S HP892XX USRGUIDE manual callscrn fb Chapter 6 Call Processing Subsystem CALL CONFIGURE Screen ...
Страница 268: ...268 S HP892XX USRGUIDE manual confscrn fb Chapter 7 Configure Screen Field Descriptions ...
Страница 269: ...269 8 Signaling Decoder Screen ...
Страница 338: ...338 S HP892XX USRGUIDE manual decoscrn fb Chapter 8 Signaling Decoder Screen Tone Sequence Decoder ...
Страница 339: ...339 9 Duplex Test Screen ...
Страница 353: ...353 10 Signaling Encoder AF Generator 2 ...
Страница 435: ...435 11 Help Screen ...
Страница 437: ...437 12 I O Configure Screen ...
Страница 443: ...443 13 Message Screen ...
Страница 445: ...445 14 Oscilloscope Screen ...
Страница 456: ...456 S HP892XX USRGUIDE manual prinscrn fb Chapter 15 Print Configure Screen Field Descriptions ...
Страница 471: ...471 17 RF Analyzer Screen ...
Страница 482: ...482 S HP892XX USRGUIDE manual rfanscrn fb Chapter 17 RF Analyzer Screen Field Descriptions ...
Страница 483: ...483 18 RF Generator Screen ...
Страница 492: ...492 S HP892XX USRGUIDE manual rfgscrn fb Chapter 18 RF Generator Screen Field Descriptions ...
Страница 493: ...493 19 RX Test Screen ...
Страница 504: ...504 S HP892XX USRGUIDE manual servscrn fb Chapter 20 Service Screen Field Descriptions ...
Страница 519: ...519 22 Tests Screen ...
Страница 548: ...548 S HP892XX USRGUIDE manual testscrn fb Chapter 22 Tests Screen ROM Programs ...
Страница 549: ...549 23 TX Test Screen ...
Страница 551: ...551 Chapter 23 TX Test Screen Field Descriptions Field Descriptions Figure 145 The TX Test Screen txscrn wmf ...
Страница 561: ...561 24 Connector Key and Knob Descriptions ...
Страница 585: ...585 25 Modifications Accessories Manuals Support ...
Страница 605: ...605 Error Messages ...
Страница 618: ...618 S HP892XX USRGUIDE manual errormsg fb Error Messages ...