Video Offset
Refer to function block P of A4 Log Amplifier Schematic Diagram (sheet 3 of 4) in the
HP
Spectrum Analyzer Component Level Information
binder.
The circuit provides a programmable video offset, with a step size of 5
from -300
to
1. On the spectrum analyzer, press
(SPAN),
ZERO SPAN,
1
[AMPLITUDE), 50
Turn the IF auto cal off.
2. Disconnect W27 (coax 3) from
and connect a signal generator to
3. Set the signal generator controls as follows:
Amplitude
. . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4. Simultaneously decrease the signal generator output and spectrum analyzer reference level
in 10
steps. At each step, the signal displayed on the spectrum analyzer should be close
to the reference level.
5. Reconnect W27 (coax 3) to
and cycle the analyzer power. Press
STOP REALIGN
when
it appears.
6. Press
and
SINGLE
on the spectrum analyzer.
7. The offset DAC,
pin 2, should now be at its default value of approximately
V. The voltage at
pin 3 should be approximately 0 V for a DAC output of
2.45 V.
8. If this default offset voltage is incorrect, DAC
is the most probable cause.
Video Output
1. On the spectrum analyzer, press
(FREQUENCY), 300
(SPAN), 100 (Hz),
10
and
2. Connect the CAL OUTPUT to the INPUT 50R.
3. Disconnect W54 (coax 2) from
Connect a test cable from
to the input of an
oscilloscope.
4. Set the oscilloscope controls as follows:
Amplitude scale
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..0 to
Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..dc
Sweep time
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ms/DIV
5. The oscilloscope should display a 4.8
sine wave.
6. Disconnect the cable from the CAL OUTPUT and connect to the INPUT
7. Broadband noise should be displayed on the oscilloscope from approximately
to
8. As the
REF
is decreased in 10
steps from -10
to -70
the noise
displayed on the oscilloscope should increase in 100
increments. If this response is not
observed, refer to “Step Gains” and “Video Offset” in this chapter.
8-16 IF Section
Содержание 8560A
Страница 93: ......
Страница 150: ... ...
Страница 178: ...4 20 Replaceable Parts ...
Страница 180: ...4 22 Replaceable Parts ...
Страница 182: ...4 24 Replaceable Parts ...
Страница 184: ...4 26 Replaceable Parts ...
Страница 186: ...4 28 Replaceable Parts ...
Страница 188: ...4 30 Replaceable Parts ...
Страница 190: ...4 32 Replaceable Parts ...
Страница 191: ......
Страница 192: ......
Страница 193: ......
Страница 194: ......
Страница 195: ......
Страница 200: ...w 5 4 A 4 w 5 5 W 2 7 Figure 5 3 Top View A2 and A3 Unfolded SK157 Major Assembly and Cable Locations 5 5 ...
Страница 205: ...Bl Figure 5 8 Rear View BTl A20 5 10 Major Assembly and Cable Locations ...
Страница 249: ...6 44 General Troubleshooting ...
Страница 250: ......
Страница 251: ......
Страница 252: ......
Страница 253: ......
Страница 282: ......
Страница 307: ......
Страница 319: ......
Страница 324: ...8 42 IF Section ...
Страница 325: ......
Страница 326: ......
Страница 327: ......
Страница 344: ......
Страница 397: ......
Страница 398: ......
Страница 423: ......
Страница 441: ...12 18 Display Power Supply Section ...
Страница 442: ......
Страница 443: ......
Страница 449: ...A 6 Component Level Information Packets ...
Страница 450: ......