WINDOW
Lets you select which states are stored by the analyzer.
WINDOW allows you to selectively toggle analyzer operation. When enabled,
the analyzer will recognize sequence terms, trigger terms, and will store
states. When disabled, the analyzer is effectively off, and only looks for a
particular enable term.
You specify windowing by selecting an enable qualifier term; the analyzer will
trigger or store all states after this term is satisfied. If the disable term
occurs after the analyzer is enabled, the analyzer will then stop storing states,
and will not recognize trigger or sequence terms. You may specify only one
enable term and one disable term.
The analyzer defaults to recognizing all states. If you specify enable, you
must supply a qualifier term. If you then specify disable, you must specify a
qualifier term.
The parameters are as follows:
disable
Allows you to specify the term which will stop the analyzer from recognizing
states once the enable term has been found.
enable
Allows you to specify the term which will enable the analyzer to begin
monitoring states.
QUALIFIER
Specifies the actual address, data, status value or range of values that cause
the analyzer to enable or disable recognition of states. Note that the enable
qualifier can be different from the disable qualifier. Refer to the QUALIFIER
syntax pages for further details on analyzer qualifier specification.
Examples
trace enable _rand disable 0ecch
See Also
The
trace
command and the SEQUENCING and QUALIFIER syntax
descriptions.
Emulator/Analyzer Interface Commands
WINDOW
443
Содержание 64782
Страница 2: ...User s Guide for the Graphical User Interface HP 64782 MC6833x Emulation Analysis ...
Страница 22: ...Part 1 Quick Start Guide 21 ...
Страница 23: ...A one glance overview of the product and a few task instructions to help you get comfortable Part 1 22 ...
Страница 24: ...1 Getting Started 23 ...
Страница 50: ...Part 2 User s Guide 49 ...
Страница 51: ...A complete set of task instructions and problem solving guidelines with a few basic concepts Part 2 50 ...
Страница 52: ...2 Plugging into a Target System 51 ...
Страница 54: ...3 Starting and Exiting HP 64700 Interfaces 53 ...
Страница 64: ...4 Entering Commands 63 ...
Страница 94: ...5 Configuring the Emulator 93 ...
Страница 133: ...132 ...
Страница 134: ...6 Using the Emulator 133 ...
Страница 194: ...7 Using the Emulation Analyzer 193 ...
Страница 255: ...254 ...
Страница 256: ...8 Making Software Performance Measurements 255 ...
Страница 290: ...9 Using the External State Analyzer 289 ...
Страница 303: ...302 ...
Страница 304: ...10 Making Coordinated Measurements 303 ...
Страница 321: ...320 ...
Страница 322: ...11 Setting X Resources 321 ...
Страница 336: ...Part 3 Reference 335 ...
Страница 337: ...Descriptions of the product in a dictionary or encyclopedia format Part 3 336 ...
Страница 338: ...12 Emulator Analyzer Interface Commands 337 ...
Страница 415: ...set Emulator Analyzer Interface Commands set 414 ...
Страница 429: ... SYMB Emulator Analyzer Interface Commands SYMB 428 ...
Страница 445: ...444 ...
Страница 446: ...13 Error Messages 445 ...
Страница 489: ...488 ...
Страница 490: ...Part 4 Concept Guide 489 ...
Страница 491: ...Topics that explain concepts and apply them to advanced tasks Part 4 490 ...
Страница 492: ...14 Concepts 491 ...
Страница 507: ...506 ...
Страница 508: ...Part 5 Installation Guide 507 ...
Страница 509: ...Instructions for installing and configuring the product Part 5 508 ...
Страница 510: ...15 Installation 509 ...
Страница 527: ...526 ...
Страница 528: ...16 Installing Updating Emulator Firmware 527 ...
Страница 535: ...534 ...
Страница 539: ...538 ...
Страница 549: ...548 ...